Ejemplo de salida:
# rssdm -T B138.00.04.ubi -n 1
Trying to update from current firmware B206.02.04 to B207.28.04.
Are you sure you want to continue(Y|N):y
Unified Image update for drive 1 will take a few seconds to
complete.
Please wait
........................................................
Drive Id
: 1
Unified image update operation completed successfully.
Power cycle the server for the downloaded Unified Image to take
effect.
CMD_STATUS
: Success
STATUS_CODE
: 0
Copyright (C) 2013 Micron Technology, Inc.
#
# rssdm -L -n 1
Drive Id
Device Name
Model No
EMC Model No
Serial No
FW-Rev
Total Size
Drive Status
PCI Path (B:D:F)
Vendor
Temp(C)
Drive Id
: 1
Drive information is retrieved successfully
CMD_STATUS
: Success
STATUS_CODE
: 0
Configuración de XtremSF350S\700S\700\1400
: 1
: rssda
: EMC P420m-MTFDGAR700MAX
: PCIEHHM-700M
: 00000000131102046D8F
: B2072804
: 700.15GB
: Drive is in good health
: 83:00.0
: EMC
: 44