Configuration 2 - Room Thermostat - Palazzetti Ecofire TWIGGY Manual De Instalación Y Mantenimiento

Twiggy
Ocultar thumbs Ver también para Ecofire TWIGGY:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.2 Configuration 2 - Room thermostat

In configuration 2 the appliance is controlled by
an external thermostat (or chronothermostat)
(not supplied) which turns the appliance on and
off according to the temperature set (Fig. 31).
When the temperature is satisfied, the thermo-
stat opens the circuit and switches off the stove.
The stove switches back on automatically when
the temperature falls below the value set on the
external thermostat (closed circuit).
This configuration can also be used to turn
the appliance on and off manually or in a pro-
grammed way (with the Timer function active)
without the aid of an external thermostat, to do
this it is necessary to put a bridge between the
two terminals.
If the thermostat allows scheduled
programming, to avoid overlapping
operation time slots, it is advisable to
deactivate the appliance timer by set-
ting it to OFF.
54
6
Termostato esterno
1
Sonda temperatura
ambiente
6
5
4
3
2
1
In this configuration the appliance
turns off when the external thermo-
stat is satisfied, or it will modulate the
power (to keep consumption to a mini-
mum) when the set water temperature
is reached.