The polluted air is taken in by the suction hood and enters into the filter unit. The operator can adjust the
suction hood to every position within his reach. The extraction power can be regulated with the help of
the regulating flap that is integrated in the hood.
In the filter unit, the gross dust particles are separated in the gross filter (pos. 10), while the finer dusts are
separated in the prefilter (pos. 11). An activated carbon filter (pos. 12) is inserted between the prefilter and
the main filter in order to absorb gases. The main filter (pos. 13) separates very fine fume particles with a
separation efficiency of more than 99 %.
The cleaned air is returned to the working space via the outlet grid at the back of the unit.
Attention!
As soon as, due to the separated particles, the resistance of the filter has achieved
a maximum value, the integrated monitoring electronics triggers off the alarm
of the signal horn (pos. 3) indicating that the filters must be replaced (see chapter
„Maintenance").