ADDITIONAL PROGRAMMING
Reset Master Code
Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the frequency and
encryption type. After resetting the Master Code, the keypad will not operate any previously programmed operators until they
are reprogrammed. To reset the Master Code to the factory default (888888):
1. Unlock and remove the faceplate.
2. Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the Master Code has
been reset.
Reset Keypad
Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and encryption
settings. All settings will be set to factory default. After resetting, the keypad will not operate the previously programmed
operators until they are reprogrammed. To reset the keypad:
1. Unlock and remove the faceplate.
2. Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release.
3. Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the keypad has
been reset.
Lockout Mode (Default is ON)
If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any keypad inputs
for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs.
Programming Step
1. Enter program mode
2. Set Lockout mode to ON:
3. Exit Program Mode
Programming Step
1. Enter program mode
2. Set Lockout mode to OFF:
3. Exit Program Mode
Constant Pressure Override (CPO)
The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in
order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of
sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster
monitored photoelectric sensors and LiftMaster monitored wired and wireless safety edge sensors. Be sure to repair or
replace these devices promptly if they are not working properly.
CPO is only compatible with LiftMaster UL 325 Compliant Gate Operators (with burgundy boards) that require monitored
entrapment protection.
To use Constant Pressure Override:
1. Enter a valid 4-digit PIN.
2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will
sound until limit is met and/or # is released.
3. The operator will stop when either the operator reaches a limit or the user releases #.
Party Mode (Gate Hold Open Feature)
Party mode can now be enabled from a model KPW5 or KPW250 wireless keypad.
Simply program the keypad into the receiver. When the gate is in the open position and the timer is running, enter a valid
4-digit PIN. The operator will chirp indicating the timer is canceled.
To restart the gate, either re-enter the 4-digit PIN, activate a hard input or a programmed remote control.
NOTE: Party Mode is only compatible with LiftMaster UL 325 Compliant Gate Operators (burgundy boards, with operator
firmware version 4.2 or higher).
Keystroke Combination
#
(Master Code)
*
02 # 1 #
#
* *
Keystroke Combination
#
(Master Code)
*
02 # 0 #
#
* *
5
Indicator
Long tone
Long tone
Keypad backlight will turn off
Indicator
Long tone
Long tone
Keypad backlight will turn off