Service Interval - Craftsman professional 921.16476 Manual Del Usuario

Ocultar thumbs Ver también para 921.16476:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CLEANING THE AIR FILTER
A dirty air filter will reduce the compressor's performance and
life. To avoid any internal contamination of the pump, the filter
should be cleaned frequently, and replaced on a regular basis.
Felt filters should be cleaned in warm, soapy water, rinsed, and
allowed to air dry before reinstallation. Paper filters should be
replaced when dirty. Do not allow the filter to become filled with
dirt or paint. If the filter becomes filled with paint, it should be
replaced. Direct exposure to dirty conditions or painting areas will
void your warranty.
CHECKING THE RELIEF VALVE
Pull the tank safety valve daily to ensure that it is operating
properly and to clear the valve of any possible obstructions.
TESTING FOR LEAKS
Check that all connections are tight. A small leak in any of
the hoses, transfer tubes, or pipe connections will substantially
reduce the performance of your air compressor. If you suspect a
leak, spray a small amount of soapy water around the area of the
suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not over tighten any
connections.
STORAGE
Before storing the compressor for a prolonged period, use an
air blow gun to clean all dust and debris from the compressor.
Disconnect the power cord and coil it up. Pull the tank safety
valve to release all pressure from the tank. Drain all moisture
from the tank. Clean the filter element and filter housing; replace
the element if necessary. Drain the oil from the pump crankcase
and replace it with new oil. Cover the entire unit to protect it from
moisture and dust.
Perform the following maintenance at the intervals indicated below.
Inspect air filter (clean or replace as necessary)
Check pump oil level
Change pump oil (Use synthetic, non-detergent air compressor oil)
Operate the tank safety valve
Check belt tension
Drain tank
Check and tighten all bolts (do not over tighten)
200-2794
MAINTENANCE

SERVICE INTERVAL

11
Daily or after
Every 100
each use
operating hours

Publicidad

Tabla de contenido
loading

Tabla de contenido