Maintenance Instructions; Storage Instructions; Troubleshooting - RedFuel SL1 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

JUMP START READY – The jump start
button has been pressed, unit is correctly
connected to a car battery, and the
internal battery is higher than 12.7V.

11. MAINTENANCE INSTRUCTIONS

11.1 After use and before performing
maintenance, unplug and disconnect
the unit.
11.2 Use a dry cloth to wipe all battery
corrosion and other dirt or oil from the

12. STORAGE INSTRUCTIONS

12.1 Charge battery to full capacity before
storage.
12.2 Store this unit at temperatures between
41° F- 68° F (5° C - 20° C).
12.3 Never completely discharge the battery.

13. TROUBLESHOOTING

PROBLEM
When recharging the
unit, the display shows
BATTERY TOO HOT
TO CHARGE.
When recharging the
unit, the display shows
BATTERY TOO COLD
TO CHARGE.
Alarm is sounding
and display shows
WARNING CLAMPS
REVERSED.
The unit won't jump
start my car.
POSSIBLE CAUSE
When the internal temperature is
too high, the unit shuts down to
protect itself from damage.
The internal battery's temperature
is too low.
Connections are reversed.
Clamps are not making a good
connection to the battery.
The internal battery is not
charged.
The temperature of the internal
battery is above 113°F (45°C).
The vehicle's battery voltage is
over 15V.
The outside temperature is less
than 41°F (5°C).
The vehicle's battery is defective.
10 – Maximum 10-second-down counter
for engine start.
BATTERY RECOVERY XXX SEC
REMAINING – Shows waiting time needed
before attempting another engine start.
battery clamps, cords, and the outer case.
11.3 Do not open the unit, as there are no user-
serviceable parts; any servicing should be
performed by qualified service personnel.
12.4 Charge after each use.
12.5 Charge at least once every 3 to 6 months
if not in frequent use, to prevent over-
discharge.
Disconnect unit. Move the unit to
a cooler, well-ventilated location
and allow it to cool down before
attempting to recharge.
Disconnect unit. Move the unit
to a warmer, well-ventilated
location and allow it to warm up
before attempting to recharge.
Disconnect the unit and reverse
the clamps.
Check for poor connection to
battery and frame. Make sure
connection points are clean.
Check the battery charge status
and recharge, if necessary.
Place the unit in a well-ventilated
area, to cool the battery.
You cannot use this jump starter
for this vehicle.
Try starting several times. If not
successful, place the unit in a
warmer area for a short time.
Have the battery checked.
• 8 •
REASON/SOLUTION

Publicidad

Tabla de contenido
loading

Tabla de contenido