Installation Guide /
Guía de instalación
for Oberon Model 1043-ANTMNT & 1043-FL
para Modelo Oberon 1043-ANTMNT & 1043-FL
1
Place the enclosure assembly on the work surface. Remove one of the 1"
trade size hole cover on the side of the enclosure and install the 1" trade
size conduit connector (the side on which the trade size cable clamp is to be
installed will be determined by the location the enclosure is to be installed
and direction from which conduit will be brought into the enclosure)
Attach box mounting bracket to studs and secure the back box to the brack-
et using self-tapping screws.
NOTE: The sheetrock that will be installed over the access point enclosure
will require a 11.25" x 11.25" opening be cut to accommodate the enclosure
(special cutting tools may be required. Adjust the location of the enclosure
on the studs in a way that assures that the bottom surface of the enclosure
is flush with or slightly above the bottom surface of the sheetrock.
NOTE: A surface mount box (or biscuit jack) and equipment cord can be
conveniently mounted inside the Model 1043. (Non-plenum rated cables can
be used inside a plenum rated enclosure). Use an adhesive backed surface
mount box. Consider bend radius of horizontal cable and equipment cord
when attaching the surface mount box.
Coloque el ensamblaje del gabinete en la superficie de trabajo. Retire una
de las cubiertas de orificio de tamaño comercial de 1" en el lado del gabi-
nete e instale el conector del conducto de tamaño comercial de 1" (el lado
en el que se instalará la abrazadera del cable de tamaño comercial se de-
terminará según la ubicación en la que se ubicará el gabinete instalado y la
dirección desde la cual se llevará el conducto al recinto).
Fije el soporte de montaje de la caja a los montantes y asegure la caja pos-
terior al soporte con tornillos autorroscantes.
NOTA: La placa de yeso que se instalará sobre el gabinete del punto de
acceso requerirá que se corte una abertura de 11.25" x 11.25" para acomo-
dar el gabinete (es posible que se requieran herramientas de corte especial-
es. Ajuste la ubicación del gabinete en los pernos de una manera que
asegure que la superficie inferior del recinto está al ras o ligeramente por
encima de la superficie inferior de la placa de yeso.
"Oberon" and all other marks where denoted are trademarks of Oberon Inc.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. ©1999-2020 Oberon Incorporated. Todos los derechos reserve.
1 cont.
NOTA: Una caja de montaje en superficie (o un conector para galletas) y
un cable de equipo se pueden montar convenientemente dentro del
Modelo 1043. (Los cables sin capacidad de plenum se pueden usar den-
tro de un recinto con capacidad de plenum) Use una caja de montaje en
superficie con respaldo adhesivo. Considere el radio de curvatura del
cable horizontal y del cable del equipo cuando conecte la caja de mon-
taje en superficie.
2
Clamp the firestop grommet around the cable far enough to allow attach-
ment to the access point (8" - 10"). Insert the grommet into the conduit
fitting.
Sujete la arandela cortafuegos alrededor del cable lo suficiente para
permitir la fijación al punto de acceso (8" - 10"). Inserte la arandela en el
accesorio del conducto.
3a
©1999-2020 Oberon Incorporated. All rights reserved.
EPN 3109 & 3936 - Rev. 8/14/2020
3a Cont.
(1043-FL ONLY) The 1043-FL comes with two (2) mounting plate op-
tions. For Cisco access points, use the flat mounting plate (with keyhole
slots), and for Aruba and all other access points, use the T-Bar mount.
Fasten the mount to the 1043 assembly using two (2) provided #8-32
screws.
(For Cisco AIR-BRACKETS-1 and 2 ONLY) Attach the Cisco AIR-
BRACKET-1 or 2 to the mounting plate using four (4) provided #8-32
screws.
Attach the access point to the mounting plate or AIR-BRACKET-1 or 2.
Attach the Ethernet cable to the access point.
(SOLO 1043-FL) El 1043-FL viene con dos (2) opciones de placa de
montaje. Para los puntos de acceso de Cisco, use la placa de montaje
plana (con ranuras de ojo de cerradura), y para Aruba y todos los demás
puntos de acceso, use el soporte de barra en T. Sujete el soporte al
ensamblaje 1043 con dos (2) tornillos #8-32 provistos.
(SOLO para Cisco AIR-BRACKETS-1 y 2 SOLAMENTE) Fije el Cisco
AIR-BRACKET-1 o 2 a la placa de montaje con cuatro (4) tornillos #8-32
provistos.
Fije el punto de acceso a la placa de montaje o AIR-BRACKET-1 o 2.
Conecte el cable Ethernet al punto de acceso.
3b
(1043-ANTMNT ONLY) The 1043-ANTMNT comes with a T-Bar mount.
Fasten the mount to the 1043 assembly using two (2) provided #8-32
screws. Attach the access point to the mounting plate.
Attach the Ethernet cable to the access point.
(SOLO 1043-ANTMNT) El 1043-ANTMNT viene con un soporte de barra
en T. Sujete el soporte al ensamblaje 1043 con dos (2) tornillos #8-32
provistos. Fije el punto de acceso a la placa de montaje.
Conecte el cable Ethernet al punto de acceso.
Mounting Solutions for WiFi Access Points
4
NOTE: Step 4 applies only to the 1043-ANTMNT.
Remove the required number of knockouts from the ANTMNT trim. Attach
the WiFi or DAS antenna(s) through the openings. Jumpers will be required
to connect the antenna to the access point's antenna connectors.
NOTA: El paso 4 se aplica solo al 1043-ANTMNT.
Elimine el número requerido de perforaciones del ajuste ANTMNT. Conec-
te las antenas WiFi o DAS a través de las aberturas. Se necesitarán puen-
tes para conectar la antena a los conectores de antena del punto de acce-
so.