12:1 MULTI-LASER INFRARED THERMOMETER
Please remember to keep away from children and don't use it for safety related applications.
1. Simply aim the thermometer at the target with Lens and press Meas. key to display the surface temp.
2. Please make sure the target area is within the appropriate field of view.
Press the Mode Key for scrolling through display functions.
Shows the emissivity data. (The default emissivity is 0.95)
E
↑E↓
Press the Mode key, then press the Up key or Down key to set the emissivity, then press the Mode key to
confirm. The emissivity can be changed from 0.10 (10E) to 1 (100E.)
MAX
Press Mode key for Maximum (MAX), Minimum (MIN), Different between MAX and Min (DIF) and Average
MIN
(AVG) modes. During the measurement, the special modes reading will be displayed beside the mode icon.
dif
AVG
Press the Up key or the Down key to change the High Alarm (HAL) or Lo Alarm (LAL), then press Meas. key to
HAL
confirm. When reading is outside the High Alarm (HAL) or Lo Alarm (LAL) limit the high or low icon will flash
LAL
and you will hear a beep.
*The thermometer will automatically shut off if left idle for more than 60 seconds.
In E, MAX, MIN, DIF, AVG mode
In MAX, MIN mode: Hold the Meas. key
Backlight
Measure Key
CAUTION
1. When device is in use, do not look directly into the laser beam. Permanent eye damage may result.
2. Use extreme caution when operating the laser.
3. Never point the device towards anyone's eyes.
4. Keep out of reach of all children.
STORAGE & CLEANING
Unit should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should
be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water
or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do no submerge any part of the
thermometer.
2
LCD
Mode
˚C/˚F
Lock
Press Up key for LOCK mode ON/OFF. The lock mode is particularly useful
for continuous monitoring of temperatures for up to 60 minutes.
Press Down key for ˚C or ˚F transferred.
The Bar display indicates the measuring temperature.
The bar shows RED color when the reading is close to maximum value,
and shows BLUE when close to minimum. While the temperature is
between the maximum and minimum, the bar will display in YELLOW.
LCD backlight is always on
and press the Down key for the laser function to be turned ON or OFF.
www.mastercool.com
Laser
Measure
Key
Battery
Cover
Infrared
Lens
English