Technical Data - CP PAC P 13 Instrucciones De Seguridad Y Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Safety and operating instructions

Technical data

Dimensions
Weight
Hydraulics
Engine
Change of flow rate
The flow rate can be changed from 20 l.p.m.
(5 US gal/min) to 30 l.p.m. (8 US gal/min) as follows:
1.
Loosen the screw (1).
2.
Move the POD cylinder to the alternative mark.
3.
Retighten the screw (1).
16
Height
Width
Length
Incl. oil
Flow
E.H.T.M.A. category
Nominal pressure
Standard pressure setting
Circuit type
Pump type
Oil tank capacity
Filtration
Cooling system
Type
Performance
Fuel
Engine oil
Fuel tank
Starter
705 mm (27.7 in)
600 mm (23.6 in)
745 mm (29.3 in)
91 kg (200 lb)
20-30 l.p.m. (5-8 US gal/min)
C and D
120 bar (1800 psi)
150 bar (2200 psi)
Open centre
Gear pump, directly driven from the engine
crankshaft by means of a flexible coupling
7 litres (1.8 US gal)
25µ filter in return line. Filter by-pass valve in valve
block
Thermostatically controlled air blast oil cooler
Honda GX 390 QX, air cooled 1 cylinder 4-stroke
petrol engine with oil alert system and transistor
ignition system
13 HP (9.6 kW) at 3600 rpm
Unleaded petrol
Consult engine manual
6.5 litres (1.7 US gal)
Recoil handstart
PAC P 13
339 5183 81

Publicidad

Tabla de contenido
loading

Tabla de contenido