EWR
1
1
Shunt simulator
2
Knob
Fig. 2
Connection of shunt simulator
Preparing the welding monitor:
BEI.0236.0 • 2017-11-24
2
3
PG7 plug
NOTICE
• The shunt simulator must be set to 0 A during the test. This value must not
be changed during the test.
1 Start the welding monitor and open the "Regula WM" software.
2 Select shunt type 300 A.
The welding monitor is now used to display the actual value. Measured value
acquisition is not necessary for the test, but may be performed if desired.
4
Marking for EWR connection lead
3
4
EN - 3