PROGRAMMING AND VISUALIZATION OF ON-OFF FUNCTIONING IN Rx (mV) TYPE
PROGRAMMING AND VISUALIZATION OF PROPORTIONAL FUNCTIONING IN Rx (mV) TYPE
Time base: 300 sec
Push and quickly release CAL button and scroll the menu using + and – buttons
till the display shows "Function Type". Push CAL to enter the submenu and
then, by pressing + and – button, choice "Function On-Off" and confirm pressing
CAL.
The display will show the value of setpoint stored in the last programming. Modify
it by pressing + and – button and confirm the choice pressing CAL.
The display will show the direction of socket activity Oxid or Red stored in the
last programming. Choice the direction by + or – button and confirm pressing
CAL.
Select Red if you want the controller to power on socket for mV values greater
than Setpoint.
Select Oxid if you want the controller to power on socket for values of mV lower
than Setpoint.
The display will show the % flow rate stored in the last programming. Modify it by
pressing + and – button and confirm the choice pressing CAL.
The display will show the value of "Delay On" stored in the last programming.
This parameter means the number of seconds that the controller will wait until
power on the socket when the measure will overtake the setpoint. Modify it by
pressing + and – button and confirm the choice pressing CAL.
Push ESC button to esc the menu and go back in measure with the On-Off
functioning just programmed.
In the On-Off functioning if the controller is activating the socket the display
shows "On" and the % flow rate programmed on the first row, if the controller is
not activating the socket the display shows "Off" and the % flow rate
programmed.
On the second row the display writes the measure.
Range of proportionality = 100mV
Time base: 300 sec
Push and quickly release CAL button and scroll the menu using + and – buttons
till the display shows "Function Type". Push CAL to enter the submenu and
then, by pressing + and – button, choice "Function Prop" and confirm pressing
CAL.
The display will show the value of setpoint stored in the last programming. Modify
it by pressing + and – button and confirm the choice pressing CAL.
The display will show the direction of socket activity Oxid or Red stored in the
last programming. Choice the direction by + or – button and confirm pressing
CAL.
Select Red if you want the controller to power on socket for mV values greater
than Setpoint.
Select Oxid if you want the controller to power on socket for values of mV lower
than Setpoint.
The display will show the value of "Delay On" stored in the last programming.
This parameter means the number of seconds that the controller will wait until
power on the socket when the measure will overtake the setpoint. Modify it by
pressing + and – button and confirm the choice pressing CAL.
Push ESC button to esc the menu and go back in measure with the Proportional
functioning just programmed.
In the Proportional function the display shows on the first row "Prop" and the
actual % socket activity. The % activity is calculated according to the measure
sampled at the beginning of the activity cycle.
On the second row the display writes the measure.