2. Remove the cover by rasing it a slight angle until the upper securing tab is
freed (see figure nº 2). Remove the cover in a vertical direction without striking
the inside of the machine (see figure nº3).
WARNING: when the cover is removed, live parts of the appliance are
exposed.
During this operation do not:
- Damage any internal components, especially the electronic circuit housed
under the volute (see figure nº 4).
- Scratch the cover or the visor of the IR sensor.
The appliance's electrical installation is made via rear channelling (figure nº 5),
as follows:
1. Drill four Ø 8 mm (Ø 0.31") holes using the
supplied template. Clean up the holes once they
have been made. Insert the four plugs until they
are flush with the surface (see figure 6).
2. Pass the 3 electric cables (3 cables 16 AWG/105ºC)
from the wall through the entrance hole (Ø 22 mm - Ø 0.87")
as figure nº 8 shows.
Means for disconnection with contact separations at least 3 mm (0.12")
must be incorporated in the fixing wiring.
During the installation process, the protection areas should
be considered according to Standard VDE 0100.
3. Assure that the four silent blocks of the base-plate are properly
located. Screw in the four supplied screws to firmly secure the
base of the appliance to the wall (see figure 7).
4. Connect the Neutral and Line (N, L) wires to the terminal block
and the A/V cable to the earth connection screw (Class I) as figure
nº 8 shows.