12. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
Cold water inlet valve is incorrectly
orientated (if present)
No water in the tank
High Limit Switch activated
Faulty element
Incorrect wiring
No / insuffi cient electricity supply
No hot water
Faulty thermostat
Heavy calcifi cation
Blocked ports or non return valve
Thermomixer valve set too cold
Circuit breaker has blown
No power as water heater is
activated while engine is not running
Circuit breaker tripped due to low
power or insuffi cient water supply
No output from tank Air lock
Insuffi cient water in the tank
Wrong breaker amperage
High limit Switch
continually trips
Faulty element
Heavy calcifi cation in water tank
Faulty wiring
Initial use
Faulty / old valve
Pressure relief
Valve (TMP/TMV)
Water Heater left constantly on
Leaking
Tank not winterized
Electric thermostatic controls faulty
Damage to tank due to improper
service
Electrolysis due to absent or faulty
galvonic isolator
Leaking tank
No anode fi tted to tank
Corrosion or damage due to tank
not winterized properly
Fittings not correctly attached

13. SERVICE SUPPORT DETAILS

For installation or service advice please contact Whale® Customer Support:
UK Tel: +44 (0)28 9127 0531
UK Email: info@whalepumps.com

14. PATENTS AND TRADEMARKS

Whale® is a registered trademark of Munster Simms Engineering limited.
POTENTIAL SOLUTION
Ensure check valve is the correct orientation (if
present).
Fill the tank with water.
Press reset and try again. If this has no effect, contact a
local electrician to replace the switch or element.
Replace element.
Check wiring and contact a marine electrician.
Contact a marine electrician to check the electrical
supply.
Replace the thermostat (Section 13).
Flush your hot water heater. If this has no affect,
replace the heating element (section 10).
Clear the blockage.
Adjust to between 40ºC (104ºF) and 55ºC (131ºF).
Check and replace if necessary.
Recharge batteries and only use the water heater while
the engine is activated.
Fill the water tank fully and only use while engine is
running.
Bleed the system.
Check non-return valve is not blocked and fi ll tank to
capacity.
Check fuse rating to ensure correct amperage and
replace if necessary.
Replace element.
Flush and clean regularly.
Have a marine electrician check the electric circuit.
The T&P valve may leak on initial use until it seals itself.
Open the valve and re-run the system.
Replace the valve.
Replace valve (due to deposit build-up on valve seat)
and do not leave Water Heater constantly 'on'.
Replace valve and winterize tank in future.
Have a marine electrician check the system.
Replace Water Heater.
Replace Water Heater and install galvanic isolator.
Replace Water Heater and fi t anode in drain valve fi tting
Replace Water Heater and ensure it is winterized in
future.
Check all connections are water-tight.