Troubleshooting Guide
Symptom
Hot water warning
Tilt warning
Flames out warning
Low battery warning
Low water flow warning
Burner will not light
Water leakage
Hose turns white or
discolors inside
Battery won't hold a Charge
No display
Technical Characteristics
Pressure: 2.8 kPa
Injector size: 0.026 in (0.66 mm)
Total gas consumption: 21.0 MJ/h
Gas type: Propane LPG
Replacement Parts
Parts List
1.
2000028448
Shower
2.
2000027851
Li-Ion Battery
3.
2000027849
Pump Assembly
4.
2000028470
Adapter – 120V
5.
2000027848
Adapter – 12V
10
Possible Cause
Water tank/carrier is running out of water
Environment temperature is high
Temperature sensor defective
Heater is tilted more than 30 degrees.
Sensor defective
Flames blown out by strong wind / pilot light is
out
Flame detection module defective
Battery voltage lower than 9.8V.
Defective battery
Pump is not in correct position
Water tank/carrier out of water
Pump inlet screen clogged
Hose twisted / kinked
Battery lead disconnected
Pump power cord disconnected
Low battery
Flow rate sensor defective
Propane cylinder empty
Propane cylinder frosted
Fuse defective
Electronic circuit defective
Connectors cross-threaded;
Sleeved-connectors were not locked into place
Defective seal or break
Calcium buildup
Defective Battery
Main power switch is neglected
Battery lead disconnected
Fuse defective
Electronic circuit defective
Low battery
Main power switch at "OFF" position (for model
2302-A only)
6.
7.
8.
9.
10. 2000028606
Fill water tank/carrier with water.
Turn control knob to a cooler setting.
Contact Coleman if under warranty.
Gas & pump will be shut off immediately.
Contact Coleman if under warranty.
Do not use in strong wind condition. Turn off the heater completely and restart the ignition
sequence.
Contact Coleman if under warranty.
Recharge the battery.
Contact Coleman if under warranty.
Rotate pump so "THIS SIDE UP" is facing upward.
Fill water tank/carrier with water.
Clean the screen, seen instructions given in maintenance section.
Straighten hose.
Remove battery cover & reinstall lead.
Plug cord into power socket on heater.
Recharge the battery.
Contact Coleman if under warranty.
Replace cylinder.
Replace cylinder and reuse after thawing.
Refer to maintenance section and replace the fuse.
Use Match Lighting instructions in the USE AND OPERATION section. If still not lighting,
contact Coleman if under warranty.
Reconnect the connectors.
Read instructions for connecting sleeved connectors and reconnect the connectors.
Replace sealing components (O-rings) or send to Coleman when necessary
Clean heater (refer to section "cleaning instructions" on page 7)
Contact Coleman if under warranty.
See Helpful Hints section on how to use the main power switch
Remove battery cover & reinstall lead
Refer to maintenance section and replace the fuse.
Contact Coleman if under warranty.
Recharge the battery.
Turn on the main power switch
2000014870
Water Carrier
2000027845
Shower Arm
2000027844
Fuse
2000027842
Shower Assembly Carry bag
Shower Hose
- Contact Coleman -
www.coleman.com | 1-800-835-3278 | TDD 316-832-8707
Solution