INSTALLATION

COMMISSIONING

 Insert the coding plug to the desired performance.
Stage 1
208 V
5.4 kW
Stage 2
208 V
7.2 kW
 Mark the selected output power and voltage on the type
plate with a permanent marker.

6.2 Temperature setting/anti-scalding protection

 Connect the lead of the electronic temperature control to
position „A1" in order to get the maximum outlet tempera-
ture of 140 °F (60 °C).
The maximum temperature can be limited to 109 °F (43 °C):
 Connect the lead of the electronic temperature control to
position „A2".
 Reinstall the plastic cover.
7.
Commissioning
DANGER Electrocution
Commissioning must only be carried out by an author-
ised contractor in accordance with safety regulations.
!
Damage to the appliance and the environment
Open hot water faucet for a few minutes until water fl ow
is continuous and all air is purged from water pipes. The
appliance's plastic cover must be installed before the
circuit breaker is turned on.
 Turn on circuit breaker to bring electrical power to the
appliance.
 Turn the temperature selector clockwise and anti-clockwise,
to calibrate the temperatur selector.
 Adjust the water temperature to the desired level using the
knob on the front cover of the appliance.
 Turn on hot water and wait twenty seconds until tempera-
ture has stabilized.
WWW.APTANKLESS.COM
220 V
230 V
240 V
6.0 kW
6.6 kW
7.2 kW
220 V
230 V
240 V
8.1 kW
8.8 kW
9.6 kW
 Check the water temperature with your hand and make sure
that it does not feel too hot. Reduce temperature if this is
necessary. A setting of 108 °F - 116 °F (42 - 47 °C) is recom-
mended for most applications.
 Explain to the user how the appliance works and familiarise
him or her with its use.
 Advise the user about possible hazards (hot water tempera-
ture up to 140 °F (60 °C). Hand over these instructions, to be
kept for future reference.
 A setting of 108 °F - 116 °F (42 - 47 °C) is recommended for
most applications.
7.1

Appliance handover

Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and in-
stallation instructions to the user.

8. Troubleshooting

Danger of electrocution
To test the appliance, it must be supplied with power.
8.1
Display options LED diagnostic „traffi c lights"
Display options
red
illuminates in case of faults
yellow
illuminates when the appliance is heating water
green
flashing: The appliance is supplied with power
1 LED diagnostic „traffi c lights"