Specifications:
Size:
5280
5280-MG
Weight: 5280
5280-MG
Input Voltage:
12 to 24 VDC systems
Input Current:
3.7 Amps Maximum (+12.8VDC)
Maximum power consumption: 47 watts (+12.8VDC)
Flash Rate:
Per Hybrid Module:
5280: 120 cycles/minute
Temp. Range:
-30°C to +50°C
Installation & Mounting:
Important!
This unit is a safety device, and it must be
connected to its own separate, fused power point to assure
its continued operation should any other electrical acces-
sory fail.
Carefully remove the minibar and place it on a flat surface. Exam-
ine the unit for transit damage, and locate all parts. If damage is
found, or parts are missing, contact the transit company or ECCO.
Do not use damaged or broken parts.
!
Caution! When drilling into any vehicle surface,
make sure that the area is free from any electrical wires, fuel
lines, vehicle upholstery, etc. that could be damaged.
Permanent Mounting:
1. Select the desired location on a flat surface for the
minibar to be mounted. The visibility of the LED hybrid flash
and ease of wiring access should be taken into
consideration in the selection of the mounting location.
2. Using the minibar base as a template, mark the four
mounting hole locations (see Figure 1).
3. Drill the holes using a 7/32" drill size.
4. A fourth hole may be drilled for wire access as shown in
Figure 1, and the wires may be routed through the grom-
met.
5. Connect the power wires as shown in the wiring section
(see Figure 2).
6. Mount the minibar with #10 hardware.
920-0098-00 Rev. C
13.3"L x 6.3"W x 5.8"H
15.2"L x 6.4"W x 6.1"H
approx. 4.4 lbs.
approx. 5.7 lbs.
Total:
360 cycles/minute
Temporary Mounting, Magnet Mount:
The Magnet Mount feature includes 4 magnets on the
bottom of the minibar for a secure, temporary mount. The
minibar should be placed in the center of the roof where
the least amount of curvature occurs. Before installing,
make sure there is no debris on the bottom of the minibar
or on the roof of the vehicle, which could reduce the holding
power of the magnet. Place and remove the minibar without
sliding to avoid scratching the paint on the vehicle. After
placement, the minibar should adhere firmly to the surface.
If the unit slides or moves easily, a proper installation has
not been obtained. To protect the minibar and magnet
mount assembly, return minibar to the box when not in use.
Do not attempt to attach the minibar to an ice covered
surface.
Important! The magnet mount is not recommended for
use on a moving vehicle, nor is it intended as a perma-
nent mount for the minibar. Long duration usage of the
magnet in the presence of moisture will cause the steel
to rust.
Wiring:
!
WARNING!
Failure to follow these instructions can result in fire
or injury from excessive heat build up.
•Operator is responsible for ensuring cigarette adapter
fits correctly into cigarette/auxiliary outlet used.
•For proper operation, verify cigarette/auxiliary outlet
circuit is rated to supply, a minimum of 10 amps. (See
specifications section for rated current in amperes).
•Do not exceed the current rating for the cigarette lighter
power outlet recommended by vehicle manufacturer.
•Keep cigarette lighter adapter, and outlet, clean and
free of debris.
•Do not use the cigarette lighter adapter when wet.
•Insert cigarette lighter adapter fully into the outlet for
proper connection.
•Grasp cigarette lighter adapter, NOT cord, to remove
from outlet.
•Remove cigarette lighter adapter completely from outlet
when light is not in use.
Figure 1