To Turn Off Gas To Appliance - PFS ReddyHeater BWH10NLMC Manual De Operación Y Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between 1 and 5.
The thermostatic control used on this model
differs from standard thermostats. You set
standard thermostats to a specific tempera-
ture such as 72 degrees. The thermostat
used on this heater senses the room tem-
perature. At times the room may exceed the
set temperature. If so, the burner will shut
Shutting Off Heater
Turn control knob clockwise
OFF position.
1. STOP! Read the safety information on
page 18.
2. Check that gas supply to heater is on.
3. Push in gas control knob slightly and turn
clockwise
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information on page 18. If you
do not smell gas, go to the next step.
5. Push in gas control knob slightly and turn
counterclockwise
and press for five (5) seconds
Note: The first time that the heater is oper-
ated after connecting the gas supply, the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system.
6. With control knob pressed in, push down
and release the ignitor button. This will
light pilot. If needed, keep pressing ignitor
button until pilot lights.
200211-01A
OPERATION
THERMOSTAT CONTROL OPERATION

TO TURN OFF GAS TO APPLIANCE

to the
MODEL BWH10NLMC
LIGHTING INSTRUCTIONS
to the OFF position.
to "PILOT/IGN"
www.sureheat.com
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
off. The burner will cycle back on when room
temperature drops below the set temperature.
The control knob can be set to any comfort
level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb reacts
to the temperature depending on housing
construction.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
PILOT position.
7. Keep control knob pressed for ten (10)
seconds after lighting pilot. If pilot goes
out, repeat steps 5, 6 and 7.
8. To select the desired heating level, par-
tially press down the control knob slightly
and rotate counterclockwise
Release the downward pressure on the
knob while continuing to turn until the knob
locks at the desired setting position. Do
not operate between locked positions. Set
control knob to desired heating position.
Note: Both HIGH and LOW are locked
positions. You must press in control knob
before turning it from these positions.
OFF
PILOT/IGN
Ignitor Button
Figure 21 - Control Knob in the OFF
Position
to the
HIGH
LOW
Control Knob
19
.