Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
DECLARATION BY THE MANUFACTURER
EN
Manufacturer: Ditec Entrematic Nordic AB,
Box 669,
261 25 Landskrona, Sweden
Herewith declares that the microwave non-contact push
button EMSA13 is in conformity with the provisions of the
following EC directives:
- R&TTE Directive 1999/5/EC
- EMC Directive 2004/108/EC
Landskrona, 19-05-2011
GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally com-
petent personnel only.
Read the instructions carefully before beginning to install
the product. Incorrect installation may be a source of dan-
ger.
Packaging materials (plastic, polystyrene, etc.) must not be
allowed to litter the environment and must be kept out of
the reach of children for whom they may be a source of
danger.
Before beginning the installation check that the product is
in perfect condition.
For repairs or replacements of product only original spare
parts must be used. These instruction must be kept and
forwarded to all possible future user of the system.
To handle electronic parts, wear earthed antistatic
conductive bracelets.

1. TECHNICAL DATA

Power supply
Stand-by absorption
Operating absorption
Frequency
Range
Output contact
Protection degree
Temperature
2. REFERENCE
[1] Cover
[2] Sensor support frame
[3] Detection module
[4] Command terminal board
[5] Detection area range adjustment trimmer
[6] Container
[7] LED / Operating indicator
[8] Detection mode selection switch
3. INSTALLATION AND ELECTRICAL CONNECTIONS
a round recessed box (not supplied) in a position suitable
for the designated use and placed as shown in Fig. 1 and 3.
Make the connections to the command terminal board [4],
as shown in Fig. 4.
WARNING: The product must be connected to an extra-low
voltage power source (SELV = Safety Extra Low Voltage)
which is protected from overcurrent and shortcircuiting.
Johnny Persson
Product Safety & IP Manager
24 V AC/DC
50 mA
80 mA
24,150 GHz
~ 100 mm ÷ 500 mm
30 V / 1 A max (resistive load)
IP43
da -20° C a +55°C
Fasten the sensor support frame [2] to the container using
the supplied screws.
NB: Avoid placing items that may move in the detection area
i.e. curtains, signs or plants.
4. ADJUSTMENTS
Selecting type of detection.
Select the type of detection using the selection switch [8].
T / TOGGLE: Toggle function.
until a second detection takes place.
P / PULSE: Pulse function.
A detection activates the contact for a short period of time
(approx. 1 s).
Detection area adjustment
Adjust the detection area range by using the adjustment
-
+
100
5. INDICATIONS
The LED [7] comes on when the output relay is activated.
6. TROUBLESHOOTING
Problem
Cause
It does not
Power supply vol-
work
tage
Faulty connection
It does not
Sudden change in
always work
the detection area
conditions
It works by
There is an object in
itself
the detection area
The sensor is subject
to vibrations
The sensor detects
the
moving
wing
© All rights in and to this material are the sole property of DITEC En-
are expressly forbidden without the prior written consent of DITEC
Entrematic Nordic AB. Rights reserved for changes without prior
notice.
2
-
+
500
Solution
Check the power supply
Check the wiring and
the connector
Check the installation
conditions
Check the detection
area range.
Remove the object
Adjust the detection
door
area correctly

Publicidad

Tabla de contenido
loading

Tabla de contenido