INSTALLATION EXAMPLES
It is the responsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform
as intended. All air movement devices have a performance curve. The amount of air (CFM) that an HRV/ERV will deliver is
directly related to the total external static pressure (E.S.P.) of the system. Static pressure is a measure of resistance imposed
on the blower by length of duct work/number of fittings used in duct work, duct heater etc.
Example diagram only-duct configuration may change depending on model
Fully Dedicated System
Exhaust
Bathroom
(new construction)
Bedrooms
Central Control - optional
Fresh air to living room
Stale air drawn from key areas
of home (bathroom, kitchen,
laundry)
Fresh air supplied to main liv-
ing areas
HRV/ERV must be balanced
HRV
Fresh Air
460 mm
Exhaust Air
10