Automatic For Park Operating; Automatic Operating - Hiltron security PCM100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

security
3.1.1
AUTOMATIC FOR PARKS operating
One pulse allows : opening , pause , automatic closing .
During the opening operation, other pulses will be ignored. During the closing operation,
possible pulses stop and reverse the movement of gate immediately.
A contact closed on PULSE A ( Clock function ) allows to open the gate up to the setted pause
and it be open up to the opening of the contact.
GATE
STATUS
Total Opening and
CLOSE
reclosing after the time
No effect if the opening
OPENING
Total Opening if the
opening is started by
PARTIAL
OPEN
IN PAUSE
TOTAL
The reclosing is stopped and at the end of the
OPEN
pause, it restores other 5 sec. up to the reset
IN PAUSE
CLOSING
Restarts the operating procedure before the
IN STOP
3.1.2

AUTOMATIC operating

With one pulse allows :opening, pause, automatic closing.
During opening and closing procedures, every pulse stops and reverse the movement of the
gate immediately.
During the pause, a pulse recloses the gate immediately.
GATE
STATUS
Total Opening and
reclosing after the time
CLOSE
OPENING
OPEN
IN PAUSE
CLOSING
Restarts the operating procedure before the
IN STOP
PULSE A
PULSE B
Partial Opening and
closing operation after
the time of pause
of pause
is started by the
PULSE A
the PULSE B
The reclosing is stopped
and at the end of the
Total Opening
pause it restores other 5
sec. up to the reset
The closing is stopped and the gate opens
again immediately
STOP (closing or opening)
PULSE A
PULSE B
Partial Opening and
reclosing after the time
of pause
The gate stops and it recloses immediately.
The gate recloses immediately
The gate stops and it opens immediately.
STOP (closing or opening)
(SW1=OFF - SW2=OFF)
STOP
Disables A and B pulses
and disable opening
No Effect
Stops operation
and switches to
STOP mode
Remain in STOP. The pulses A and B will be ignored.
( SW1=ON - SW2=OFF)
STOP
Disables A and B pulses
and disable opening
of pause
Stops operation
and switches to
STOP mode
Remain in STOP. The pulses A and B will be ignored.
PHOTOCELL 1 PHOTOCELL 2
See SWITCH 3 page 10
See switch 3 page 10
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
A total opening is possible.
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
Stops operation and the gate opens immediately
in open operation
The opening or closing operation are locked
PHOTOCELL 1 PHOTOCELL 2
See SWITCH 3 page 10
See switch 3 page 10
The reclosing is stopped and at the end of the
pause, it restores other 5 sec. up to the reset
Stops operation and the gate opens immediately
in open operation
The opening or closing operation are locked
Setup
ON
ON
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pcm130

Tabla de contenido