6.2 Programming parameters

PSW : parameter with significant values within the range (1 : 9999) : displays the numerical value of the password for access to the parameters of the re-
ceiver (default value: 0123);
SHT : parameter with significant values within the range (0 : 3) enables modifications to the associations of the key (PLS) of the radio control and the rel-
ative relay (REL) activated on the receiver according to the table below:
PARAMETER
SHT
0
1
2
3
wherePLS x = pushbutton x of radio control.
PMA :
parameter related to operating mode of relay A:
PMA = 0
PMA = 1
PMA = 2
DTA :
parameter related to temporal dimension of relay A activation time:
DTA = 0
DTA = 1
DTA = 2
VTA :
parameter related to numerical valve of activation time set according to the time scale selected by means of
the above parameter DTA:
value range ( 0 : 255 ), (0 default value);
The three parameters described above are repeated in the same way for the remaining relays B, C and D.
Summary of factory settings (default values)
Relay
A
B
C
D
Example of parameter programming for each relay
To program relay A with 15 sec of activation, relayB with 5 minutes activation, relay C with 1h 30 minutes and relay D in bistable mode.
The parameters must be set as follows:
Relè
A
B
C
D
Note:
- when a relay is set to bistable mode with PMx =1 (with x=A or B or C or D), parameters DT and VT are no longer significant (as the relay, if activated, is
disabLED after a limit time of 255 * (tenths of minutes) );
- should the parameter PMx=2 be used, the actuator operates in bistable mode without time limit: in this case the actuator, if previously activated, will re-
main active until a new disabling (by the user) obtained with a subsequent pressing of the transmitter respective push-button.
- during selection of a time scale, the precision error corresponds to one unit of the set scale;
- during the parameter programming procedure, reception from the radio module is disabLED: normal operation of the receiver is restored on exit from the
programming phase (exit key:) or when the parameter programming standby time elapses (approx. 60 sec, resettable each time a significant key of the
programmer is pressed);
8
A
B
PLS 1
PLS 2
PLS 4
PLS 1
PLS 3
PLS 4
PLS 2
PLS 3
monostable mode (default value) ;
bistable mode [(with preset time limit = 255* (nearly 10 minutes)]
bistable mode (without time limit),
activation time scale in seconds (default value);
activation time scale in minutes; bistable mode
activation time scale in tenths of minutes
PM
PMA = 0
PMB = 0
PMC = 0
PMD = 0
PM
PMA = 0
PMB = 0
PMC = 0
PMD = 1
Relay
C
PLS 3
PLS 2
PLS 1
PLS 4
Parameters
DT
DTA = 0
VTA = 0
DTB = 0
VTB = 0
DTC = 0
VTC = 0
DTD = 0
VTD = 0
Parametri
DT
DTA = 0
VTA = 15
DTB = 1
VTB = 5
DTC = 2
VTC = 9
DTD = 0
VTD = 0
D
PLS 4
PLS 3
PLS 2
PLS 1
VT
SHT
0
VT
SHT
0
EN