N. LED Color Coding Chart and Explanation
Number of
LED
Flashes between
Color
pauses
Steady ON while
priming feed tube
Green
(max time 2
minutes)
Steady ON while
Green
burning
Green
1x
Blinks
Green
Continuously
Green
Varies
Amber
Steady ON
Blinks
Amber
Continuously
Red
1x
Red
2x
Red
3x
Red
4x
Red
8x
12
Description
Feed Motor is running continuously.
(This primes the feed tube).
Room temperature is close to set point
and burning on lowest burnt rate.
Unit is off and ready.
Appliance is in the start up/ignition
sequence or in shutdown.
When in the automatic mode, the
number of flashes between pauses
indicates the burn rate (1 for low up to 5
for high).
Appliance is set and running at either the
minimum or maximum power levels.
Appliance is in the in
shutdown sequence.
Empty Hopper Alarm
Exhaust Probe Alarm
Ambient Probe Alarm
Missed Ignition
Exhaust Gas Over Temperature Alarm
WARNING
Fire Risk
Do NOT operate appliance:
With appliance door open.
Firepot floor open.
Do NOT store fuel:
Closer than required clearances to
combustibles to appliance
Within space required for loading or
ash removal.
7077-801D • September 17, 2019
Notes
When priming the feed system and filling
the firepot, DO NOT OVERFILL FIREPOT
.
FOR IGNITION
The unit will automatically
go into start up following the prime function.
To start appliance, follow start up sequence.
During shut down, the blowers will shut off
when the exhaust temperature has cooled.
Adjust the dial control to change the desired
room temperature.
The unit will shut off only when the hopper
runs out of fuel, the user changes the
dial control to a different state, or the unit
senses an error.
During shut down, the blowers will shut off
when the exhaust temperature has cooled.
This alarm is caused by the fire going
out from lack of fuel. See troubleshooting
section for more information.
Failed component error. See
troubleshooting section for more
information.
Failed component error. See
troubleshooting section for more
information.
There are a total of 2 tries per ignition
sequence. If after 2 tries there is no rise
in exhaust temperature this error will
occur. See the troubleshooting section for
additional information and correction.
The exhaust temperature exceed the
allowable limit. See the troubleshooting
section for more information and correction.