Ego Power+ Power+ BAX1500 Manual Del Operador página 13

Ocultar thumbs Ver también para Power+ BAX1500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

When in charging process, the LED indicator will illuminate as shown below.
Charge/ Battery status
Charge <20%
20%≤Charge<40%
40%≤Charge<60%
60%≤Charge<80%
80%≤Charge≤100%
Fully charged
Charging is abnormal.
Over Temperature
NOTE:
: On
NOTICE: When all the LED indicators turn off, please refer to EGO CHX5500 operator's
manual for problem diagnosing.
BATTERY PROTECTION
The battery circuitry protects the battery pack from extreme temperature, over-
discharge, and over-charge. To protect the battery from damage and prolong its life, the
battery pack circuitry will turn off the battery pack if it becomes overloaded or if the
temperature becomes too high during use. This may happen in extremely high torque,
binding, and stalling situations.
When charging, the battery pack will automatically shut down and all the
segments of the 5-LED fuel gauge indicator will turn off when the temperature is
over 140°F (60°C) or below (32°F) 0°C. Allow the battery pack to reach normal
temperature. Charging will begin when battery pack itself returns to 37°F (3°C) -
135°F (57°C).
#1 LED
: Off
: Flashing
DISCHARGING/UNUSED
#2 LED
#3 LED
56V BACKPACK BATTERY — BAX1500
#4 LED
#5 LED
13

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido