DAMPER LINKLOGIC
CONTROL LINK INSTRUCTIONS
1. LinkLogic
devices communicate via the power line. A phase
®
coupler is required if LinkLogic
vice (such as LinkLogic
control) are wired to opposite electrical phases.
master device.
3. Start master device link process per its installation instructions.
LED
SET
BUTTON
4. When instructed, using a small screwdriver or paperclip, press
SET button for 3-seconds to activate damper control's link
mode.
5. After exiting master device link mode, turn master device on
and off and check damper control on and off accordingly.
After link is established, damper control will remain in its initial
state until master device is turned on and off.
Damper control's LED is on when damper is open and off when
damper is closed.
6. If LinkLogic
enabled range hood does not cause damper
®
installation instructions.
A qualified HVAC contractor should also ensure the proper
operation and venting of all combustion equipment in the home.
7. LinkLogic
damper control can be linked to multiple master
®
devices. If damper control is not turning off with newly linked
master device, make sure another device is not on, which would
cause the damper to remain on (open).
8. In order to erase damper control links and return it to factory
default state, proceed as follows.
a. Remove power from damper control.
b. Press and hold SET button for 10-seconds (LED may light
when SET button is pressed and then dim to off).
c. Continue holding SET button and turn power on.
d. LED should be on when SET button is pressed and power
is applied.
e. After 3-seconds, release SET button.
f. After 3-seconds, LED should light.
g. If LED does not light, repeat this process.
®
damper control and master de-
®
enabled range hood or SmartSense
®
damper control and
®
MAINTENANCE
Regular maintenance is necessary to ensure the proper operation
of the Damper system. Failure to conduct such routine maintenance
can jeopardize the ability of the Damper to introduce fresh air into
the home. Regular maintenance should include the following
activities:
®
and open to allow fresh air to enter.
before it enters the home.
preventing the buildup of snow, leaves, or vegetation at the end
cap.
contractor inspect the Damper system for proper operation.
MODELS SMD6 • SMD8