Maintenance • Mantenimiento • Entretien • Manutenção
1
4

7
8
9
5
8


5
6
9


2

3
0
4
7
9
english
Danger!
Compressed air!
In the case of contact with quickly or
suddenly released compressed air or
in the case of bursting plant compo-
nents there is a risk of serious injury
or death.
Measures:
Depressurize the BEKOMAT unit!
Danger!
Mains voltage!
In the case of contact with uninsula-
ted parts carrying mains voltage the-
re is a risk of electric shock including
injury or death!
Measures:
De-energize the BEKOMAT unit!
Maintenance recommendations
Replace service unit (5) annually.
Remove control unit () by pres-
1
sing latching hook ().
2
Detach Bekomat from outlet ().
Remove design shell (4) (where
3
applicable) using a screw driver
(0).
Remove service unit (5) from pipe
at inlet by undoing union nut
or by undoing screws () at elbow
4
connector (7)
or
5
by undoing screws (8) at inter-
6
mediate adapter (9) which is then
detached from the service unit by
7
downward movement.
• Check if new service unit (5) matches
control unit ()
- type designation and colour of
latching hook ()
• Fit new service unit (5) in reverse
order.
Assembly:
„Control unit onto service unit"
see page 8