2
STABILIZATION
MODULE
2
MOUNTING GUIDE
1
HIGH CAPACITY UNIT
The screw size is a #12 X 1 ½" hex washer head tapping screw.
You will need a 8mm socket, there is a plug that needs to be put in after drilling the hole with a ¼" drill bit. The HCU mounting holes
(2) on the bottom measures 8 ½" center to center of the holes. This is for the inside holes that are shaped like a horseshoe so the
unit can be propped on these two screws for better handling during installation.
The top measures 11" center to center of the holes. It's suggested that the top holes are marked after the two on the bottom have
already been secured to the wall. The unit can then be set on the bottom screws and the top two holes can now be marked for
drilling. The holes from top to bottom measure 22 5/8" center to center.
2
STABILIZATION MODULE
The Stabilizer bracket top holes measures 3 3/16" center to center, the bottom two are 3 ½" center to center and 5 1/8" from top to
bottom center to center. The screw size is #8 X 1 ½"drill size for the plug is 3/16", and the screw measures 1 ¼" long.
POWER CORD
Power cord measures at 10' in length.
IMPORTANT SAFEGUARDS
• Do not connect the unit to any water source other than municipally treated water.
• To reduce the risk of fire, do not install the unit near any burner, heater or cooking appliance.
• To protect against shock do not immerse power cord in water or any other liquid.
• Before plugging power cord into 110 power outlet, make sure FLOW switch is in OFF position.
• Do not open the unit as this will void the warranty – contact your supervisor or call Tersano for repairs or assistance if required.
• Do not use the unit if it has a damaged cord or plug, if it is not working properly, or if a very strong ozone odor is present.
• Do not try to repair the unit yourself – this will void your warranty.
INSTALLATION INSTRUCTIONS
FOR INDOOR WALL MOUNT & DRY LOCATIONS ONLY
1.
Carefully remove all of the items from the cartons.
2.
Remove mounting hardware from plastic packages.
3.
Attach HCU to wall using 4 screws in flanges top and bottom. If mounting to drywall, attach to ½" plywood backer board to wall
before mounting High Capacity unit. Not to be mounted on mobile devices, hand carts, etc.
4.
Align Stabilization Module with High Capacity Unit as shown.
5.
Mount Stabilization Module bracket to wall with a minimum spacing of 1.5" from the High Capacity Unit. Mount will be 4.25"
from the closest HCU mount. Use bracket as template mark holes on wall using a ¼" drill bit. Place a blue plastic insert in each
holes (4) using a hammer. Screw brackets to wall using supplied 8 X 1 ¼" screws.
6.
Once brackets are mounted, hang Stabilization Module.
7.
Attach quick disconnect to the "Cold Water In" on Stabilization Module (facing unit, blue color fittings on left side connection).
8.
Attach connector hose supplied to right side outlet on Stabilization Module and attach opposite end to COLD WATER IN on
HCU (white color fittings into grey).
9.
Ensure that the water pressure is at minimum 30 PSI (207 kPa) and maximum 65 PSI (488 kPa). This can be checked with
a simple water pressure testing gauge available at most hardware stores. NOTE: If greater than 65 PSI, a water pressure
regulator will be required.
10. Attach hose with yellow handle to OZONE SOLUTION OUT on HCU barbed fitting - clamp is not required.
11. Attach 1/8" hose to the drain fitting located to the right side of OZONE SOLUTION OUT fitting and mount the hose to the wall
down to the sink.
12. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
NOTE
• Unit to be installed vertically as shown in the picture never horizontally. Doing so will damage the unit.
• The new hose-sets supplied with the appliance are to be used, old hose-sets should not be reused.
• Failure to follow the above installation instructions will void the warranty.
START-UP INSTRUCTIONS
Use the unit for intended use only: to fill mop buckets, auto-scrubbers, carpet extractors and spray bottles.
Install the High Capacity unit as per INSTALLATION INSTRUCTIONS above.
1.
2.
Make sure the power cord is plugged into 110v power outlet. (230v where applicable.)
3.
Ensure COLD WATER IN hose is attached to open faucet or permanent cold water source with a minimum of 30 PSI
(207 kPa) , and a maximum 65 PSI (488 kPa).
4.
To start, press FLOW switch to ON position.
5.
When SYSTEM READY indicator is GREEN, dispense into mop bucket, auto scrubber, carpet extractor or spray bottle.
6.
Shut unit off when not in use by pressing FLOW switch to OFF position. To disconnect, ensure FLOW switch is in OFF position
before removing plug from the outlet. Ensure water supply to the unit is turned off when not in use.
7.
If you encounter a red light with initial installation you may need to turn the device on and off multiple times as it sets itself.
Once set and installed it will charge thereafter.
NOTE: If you still get a red light, check that the cold water is turned on. Check that there are no kinks in the line to allow
uninterrupted flow of water. Also check that the cartridge is in properly and the protective plastic on the cartridge has been removed.
Testing was performed using a duty cycle of 5 minutes on, 25 minutes off, with a maximum 60 minutes per 24 hour periods.
Do not exceed this duty cycle.
GROUNDING INSTRUCTIONS – This appliance must be grounded. In the event of a malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord
having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed
and grounded in accordance with all local codes and ordinances.
WARNING: Risk of Electric Shock. Disconnect power before servicing.
Never block or restrict OZONE SOLUTION OUT hose with nozzle, clamp or shut-off valve. This may damage unit and will
void the warranty. Always use FLOW ON/OFF switch to start or stop flow of Stabilized Aqueous Ozone.
WARNING: Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.
Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician.
This appliance is not intended for use by children or those with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
www.tersano.com
1-800-727-8835
1
2
2
WATER IN
Above diagram is a representation only
US & International Patents & Patents Pending
High Capacity Unit &
Stabilization Module Template
Stabilization
High Capacity Unit
Module
COLD
COLD WATER IN
hose
Pressure Regulator
COLD WATER IN
QUICK
to
stabilization module
DISCONNECTS
COLD
WATER
1
IN
French and Spanish translations on back.
(HCU)
Filter Cartridge
Performance Indicators
System Ready
Service Light
System Charging
Change Sensor
Replace Stabilizer
SERVICE
FLOW
OFF
ON
FLOW OFF/ON
switch
OZONE SOLUTION OUT
OZONE SOLUTION OUT
hose
DRAIN
hose
HEIGHT RECOMMENDATION
48"
OZONE
SOLUTION
OUT
1
ELECTRICAL
PLUG
Stabilization Module
High Capacity Unit
(HCU)
System Ready
System Charging
Change Sensor
Replace Stabilizer
SERVICE
FLOW
ON
OFF
COLD WATER IN
OZONE SOLUTION OUT
Install the High Capacity Unit with
the Stabilization Module 48" from
the bottom of the unit to the floor.
1
25209 R6 JULY 2015