4. CONNECTIONS
The IR Module is the main component that connects IR Receivers, the
power adapter and IR Extender Cables to one another. All of the IR Module
connections are now explained so that you can get the most out of all of the
options available.
4.1 IR Input
IR RCVR:
standard IR input (3.5mm
jack) for the enclosed IR
Receiver
SCREW TERMINAL: IR
input for connecting up to
6 IR Receivers in parallel.
+12VDC: Red
GND: Black
STATUS: Yellow
IR DATA: White
4.2 POWER Input
12VDC: Power adapter for the IR Module (enclosed), 5VDC/200mA
STATUS: Power adapter for the status signal (not enclosed), 5-24VDC or 5-
12VAC
Some A/V equipment (eg AV Receivers) have a switched power supply
(230VAC) at the back. This output automatically turns ON and OFF
whenever the A/V device is switched ON or OFF. By connecting a power
adapter (5-24VDC or 5-12VAC) to this switched output and connecting it
with the STATUS input from the IR module, a signal is sent to the IR
Receiver. When the A/V device is switched ON, a GREEN light is lit on the
IR Receiver.
4.3 IR Output
1 – 4: four mini jack outputs for connecting the IR extension cables.
EMITTER / BLASTER: every output can be switched separately for
connecting blaster or emitter LEDs.