Further Explanations; Password Protection; Sensor/Cable Fault Information Via Display Front 4501; Advanced Functions - PR 9113 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Safety Manual
13.2

further explanations

13.2.1 password protection

13.2.2 Sensor/cable fault information via display front 4501

13.3

advanced functions

The device gives access to a number of advanced functions which can be reached
by answering "Yes" to the point "adv.set".

13.3.1 memory (mem)

13.3.2 Display setup (DISp)

13.3.3 password (paSS)

13.3.4 language (lanG)

8
9113 TeMpeRaTuRe / ma CONVeRTeR
access to the configuration can be blocked by assigning a password.
The password is saved in the device in order to ensure a high degree of
protection against unauthorised modifications to the configuration. Default
password 2008 allows access to all configuration menus.
password protection is mandatory in SIL applications.
When the function is enabled and supported by selected input type,
sensor or cable faults are displayed as Se.BR (sensor break) or Se.SH
(cable short-circuited). Sensor fault is shown independently for each
channel.
In case of sensor or cable fault the backlight flashes. This can be reset by
pressing the 3 key. When the sensor or cable fault has been remedied, the
device will return to normal operation.
In the memory menu a non-SIL configuration can be either saved or loaded
from the local memory of the 4501 display unit. Choose SaVe to store the
current configuration in the 4501 memory. press LOaD to read a previously
stored configuration in the 4501 memory and store it in the device. It is only
possible to load a configuration stored from the same type of device and
from the same version, or earlier.
The brightness contrast and the backlight can be adjusted.
Tag numbers with 5 alphanumerics can be entered for both channels.
Functional readout in line 2 (ch.1) and 3 (Ch.2) of the display can be
selected: choose between readout of input value, output current or tag no.
When selecting "aLT" the readout alternates between input value, output
current and tag no.
Here you can choose a password between 0000 and 9999 in order to protect
the device against unauthorised modifications to the configuration. The device
is delivered default without password.
In this menu you can choose between 7 different language versions of
help texts that will appear in the menu. You can choose between uK, De,
FR, IT, eS, Se and DK.
Version No. V5R0

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

9113a9113b

Tabla de contenido