6. Connecting (Cabling) Each PVP™ X3
Testing Signal and
Power Connections
Rear Panel View
Using the PVP™ X3
Test button
PVP™ X3 User Manual, Rev. 1
Each PVP™ X3 has 2 power sockets and 2 signal ports.
· The Power and Signal connections are located on the underside of the service
module of each panel.
· The Signal ports may be used interchangeably.
· Each PVP™ X3 has LED indicator lights.
· Each panel indicates a successful power connection when the Power indicator light
remains red.
· Each panel indicates video signal reception when the Signal LED indicator light blinks
green. This light should be blinking to indicate good reception.
Each PVP™ X3 also has a Test button, used to ensure all LEDs are functional. Use the
Test button on each panel to perform a self-test. If self-testing, you must perform the test
individually for each PVP™ X3. You do not need to connect to a signal or use software.
When using the Test button, make sure the PVP™ X3 is not connected to the
VIP™ Driver.
To use the Test button, you must connect the power, but do not connect the signal
cables. Press the Test button to toggle through various LED light display configurations.
Connecting (Cabling) Each PVP™
Underside of Service Access View
Power Out
Signal Connections
Signal LED indicator
Power LED indicator
Test Button
Power In