Installation Consideration; Models; Power; Installation - Olimpia splendid B0813 Manual De Instalación

Ocultar thumbs Ver también para B0813:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74

Installation consideration

Models

The UI can be programmed with the following options.
Heating Only
Cooling Only
Reversible Heat Pump

Power

The UI will be powered with 12V unregulated DC Voltage.

Installation

Step 1 — User Interface Location
Approximately 5 ft (1.5m) from floor.
Close to or in a frequently used room, preferably on an
inside partitioning wall.
On a section of wall without pipes or duct work.
User Interface should NOT be mounted.
Close to a window, on an outside wall, or next to a door
leading to the outside.
Step 2 — Install User Interface
Warning
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing User Interface, turn off all power to
equipment.
There may be more than one power to disconnect.
This selection can be done during installation.
This power is supplied to the User Interface by the Air to
Water Heat Pump.
Exposed to direct light or heat from the sun, a lamp,
fireplace, or other temperature--radiating objects
which could cause a false reading.
Close to or in direct airflow from supply registers and
return--air registers.
In areas with poor air circulation, such as behind a door
or in an alcove.
1.
Turn OFF all power to unit.
2.
If an existing User Interface is being replaced:
Remove existing User Interface from wall.
Disconnect wires from existing User Interface,
one at a time.
As each wire is disconnected, record wire
color and terminal marking.
3.
Open the UI (mounting base) to expose mounting
holes. The base can be removed to simplify
mounting. Press the thumb release at the top of the
UI and snap apart carefully to separate mounting
base from remainder of the UI.
4.
Route the UI wires through large hole in mounting
base. Level mounting base against wall and mark wall
through 2 mounting holes. See Fig. 1.
3

Publicidad

Tabla de contenido
loading

Tabla de contenido