DESCRIPTION
D
Description of the TEKNA HF PLUS monitor.
Hands-free monitor for the Plus system with button and coded panels.
j
a
k
b
l
e
m
f
n
o
g
c
p
h
j
d
i
q
4.3" TFT colour screen
-
a.
Communication with hearing aid. Set the
b.
hearing aid switch to position T.
-
Function/programming buttons.
-
c.
Microphone.
Connector fixings.
d.
j.
Brightness control.
CN4 connector (end of line).
e.
k.
Colour control.
JP1 jumper, remove in video
f.
l.
Indicator LED (two-colour):
g.
-
In call: green LED illuminated.
-
In communication: green LED blinking.
RJ-45 connector (inst with UTP
m.
-
Function press
to talk:
cable).
When is pressed, LED illuminated yellow.
SW1 DIP switches.
n.
When
is released, LED blinking yellow.
CN2 connection terminals.
o.
Advanced programming LED.
C 3
h.
p.
Monitor status LED (two-colour):
i.
Only by authorised personnel:
-
Standby: LED illuminated red.
Monitor microphone volume control.
q.
-
Call: LED illuminated green.
Monitor speaker volume control.
r.
-
Communication: LED illuminated green.
D
escription of the connection terminals.
C 3
N connection terminals:
_
Vin
V out
+
MP
VP
, +
:
Negative, positive (18Vdc power supply).
–
Vin :
Video signal input through coaxial cable.
– :
Coaxial cable mesh.
Vout :
Video signal output through coaxial cable.
Vp, Mp :
Balanced video signal (through twisted pair).
C 2
N connection terminals:
_
_
-
A
D
HZ
AP+
INT
2C A1
Audio communication.
A :
Digital communication.
D :
Door bell button input.
HZ- :
Input for auxiliary door opening button.
AP+ :
Intercom function.
INT :
Output for 2nd camera activation.
2C
Output (negative) for auxiliary device activation
A1 :
(max. consumption 50mA).
Output (negative) for auxiliary call repeater
SA :
(max. consumption 250mA).
DESCRIPTION
1
F
unction buttons.
Start/stop communication button.
With the terminal in standby: One short 1-second press activates the
monitor in function mode (for 5 seconds).
During a communication process: it activates the talk/listen function.
With the monitor in standby: One long 2-second press activates 'ringtone
TEKNA-HF PLUS
11742110
VXX
volume' mode, with a tone indicating the current volume selected. Then
18121000000
SN
ADDRESS
INTER
A1
SLAVE MASTER
ESCALERA
PISO
PUERTA
STAIR
FLOOR
DOOR
each long 2-second press (before 5 seconds elapse) selects a volume
ATENCIóN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
level: maximum, medium, minimum and no volume 'night mode' and so
WARNING.
GOLMAR S.A.
C/ Silici, 13
High Voltage. Don´t open cover
Handle only by technical service
08940 - SPAIN
on (carousel mode). Note: The 'night mode' status LED blinks red.
With the monitor in standby, function mode, call or communication: One
long 3-second press turns off the monitor. Then one short 1-second
1 2 3 4 5 6 7 8 9 10
CN2
press turns on the monitor.
CN3
( )
*
With the monitor in function mode: It activates the intercom (in the same
apartment); one long press until a confirmation tone can be heard will
call all of the monitors in the apartment. To call individual devices, press
r
the button once to call the 'master' monitor, twice to call 'slave 1' and so
on up to 5 presses to call 'slave 4'. This only functions if no call or
Auto spy if Bus busy: LED blinking
red rapidly.
communication is in progress. Note: With 'Tekna Plus' monitors (see the
TTekna HF Plus manual).
Night mode: LED blinking red.
Doctor mode: LED blinking green.
( )
*
Auxiliary device 'A1' is activated (with the terminal in standby or function,
call, communication or intercom mode).
With the monitor in standby: It enables the image from the door panel
configured as main to be viewed (if the bus is busy, the status LED of the
installation with twisted pair (see
monitor will indicate so with a few quick blinks).
the Tekna HF Plus manual).
T
With the monitor in function mode: It enables audio and video
.
communication with the door panel to be established if it has its auto
switch-on function activated. This only functions if no communication is
in progress.
In call: A slave monitor enables the image of the door panel to be captured.
N connection terminals.
With the monitor in standby: A panic call to the guard units configured to
receive such calls is made.
With the monitor in function mode: It enables a normal call to the main
unit to be made. During call reception and communication processes,
it enables the lock release to be activated.
( )
*
In advanced programming mode, the default functions of function
buttons
OPERATION
-
Call reception: During call reception, the image will appear on the master
monitor and the status LED and indicator LED
monitors will illuminate (green). If the call is not answered within 45 seconds,
the status LED on the master and slave monitors will illuminate (red) and
indicator LED
the door panel will turn off and the channel will become free.
+ SA
-
To establish communication, press button
will blink (green) and LED on the door panel will illuminate. Communication
with hearing aid:
the monitor to ensure maximum audio quality during communication with the
door panel. Remember: Set the hearing aid switch to position T.
-
Communication will last for one and a half minutes or until button
again. Once communication is complete, the monitor's status LED will
illuminate (red), indicator LED
will turn off and the channel will become free.
-
To open the door, press door release button
communication processes: one press will activate the lock release for
3 seconds and LED
and
can be changed (see the Tekna HF Plus manual).
T
on the master and slave
on the master and slave monitor(s) will turn off. LED
, indicator LED
on the monitor
.
Make sure that the hearing aid is 15-20 cm away from
on the monitor and LED on the door panel
during the call or
will also illuminate for 3 seconds.
INSTALLATION
2
I
nstallation of the terminal.
Avoid dusty or smoky environments or locations near sources of heat. The
monitor can be fixed to an electrical embedding box or directly to the wall.
Important: For further information, see the T ekna
Location
Remember to remove the protective covering
from the front of the monitor once installation is
1.60m
complete.
Surface
4 30
WIRING DIAGRAM
Tekna HF Plus
CN4
S
_
V
V
+
A
D
in
out
D1
E
+
Tekna HF Plus
CN4
S
_
V
V
+
A
D
in
out
D1
E
+
M =Master.
*
Place this power supply as
close as possible to the first
monitor.
on
FA-Plus/C or FA-Plus
PRI
SEC
~
~
-
-
+ +
is pressed
Mains
I
MPORTANT
:
For further information about the door panel, sections, distances, wiring diagrams, etc., see the T632 Plus P/T manual.
https://doc.golmar.es/search/manual/ 50122328
3
T
HF Plus manual (code 50122337).
Embedding box
Screws supplied with
the embedding box.
x
D4L-PLUS
Tekna HF Plus
(1)
JP1
CN4
_
V
V
+
A
D
D2
in
out
(1)
Remove the JP1 jumper
from all of the distributors
except the last.
D4L-PLUS
Tekna HF Plus
JP1
CN4
_
V
V
+
A
D
D2
in
out
Access panel
CN3
P
10
9
8
7
6
1
2
3
4
5
SW2
SW1
CN1
- +
-
CV2
CV1
+
D
A
A
V
V
Mesh
V
V
out
in
in-
in+
out+
out-
DC lock release