DESCRIPTION
D
escription of the TEKNA S PLUS monitor.
Monitor for the Plus system with button and coded panels.
k
a
b
l
m
c
n
g
o
h
p
d
q
i
k
Monitor status LED (two-colour):
j
j.
-
In standby: LED illuminated red.
-
Call: LED illuminated green
(master monitor).
e
-
Communication: Green LED ON.
-
Auto spy if Bus busy:
LED blinking red rapidly.
-
No volume (night mode):
f
LED blinking red.
-
Doctor mode: LED blinking
green.
Handset.
a.
Connector fixings.
k.
4.3" TFT colour screen.
b.
CN4 connector (end of line jumper).
l.
Communication with hearing aids. Set
c.
JP1 jumper, remove in video
m.
the hearing aid switch to position T.
installation with twisted pair (see
Function/programming buttons.
d.
the TTekna S Plus manual, code
e.
Telephone cord.
50122251).
Cord connector.
f.
n.
RJ-45 connector (installation with
g.
Brightness control.
UTP cable).
Colour control.
h.
o.
SW1 configuration switches.
i.
Advanced programming LED.
p.
CN2 connection terminals.
q.
CN3 connection terminals.
D
escription of the connection terminals.
CN3 connection terminals:
_
( )
Vin
V out
*
+
MP
VP
Shield
, +
:
Negative, positive (18Vdc power supply).
–
Vin :
Video signal input through coaxial cable.
( )
:
*
–
Coaxial cable
shield
.
Vout :
Video signal output through coaxial cable.
Vp, Mp :
Balanced video signal (through twisted pair).
CN2 connection terminals:
_
_
-
A
D
INT
2C A1
HZ
AP+
A :
Audio communication.
D :
Digital communication.
HZ- :
Door bell button input.
AP+ :
Input for auxiliary door opening button.
INT :
Intercom function.
2C
Output for 2nd camera activation.
A1 :
Output (negative) for auxiliary device activation
(max. consumption 50mA).
SA :
Output (negative) for auxiliary call repeater
(max. consumption 250mA).
DESCRIPTION
1
F
unction buttons.
With the monitor in standby and the handset on the hook: One long 2-
second press activates 'ringtone volume' mode, with a tone indicating
the current volume selected. Then each long 2-second press (before
TEKNA-S PLUS
11742126
V XX
.
5 seconds elapse) selects a volume level: maximum, no volume 'night
15090200000
SN
ADDRESS
INTER
A1
SLAVE MASTER
ESCALERA
PISO
PUERTA
STAIR
FLOOR
DOOR
mode,' minimum and medium, and so on (carousel mode). Note: The
ATENCIóN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
de
l ser
vicio técnico.
'night mode' status LED blinks red.
WARNING.
GOLMAR S.A
High Voltage. Don´t open cover
C/ Silici, 13
Handle only by technical service
08940 - SPAIN
With the monitor in standby (handset on or off the hook), call or
communication: One long 3-second press turns off the monitor. Then
CN4
75
Ω
SW1
one short 1-second press turns on the monitor.
1 2 3 4 5 6 7 8 9 10
CN2
JP1
( )
CN3
*
With the handset off the hook: This activates the intercom (in the same
apartment); one long press until a confirmation tone can be heard will
call all of the monitors in the apartment. To call individual devices,
press the button once to call the 'master' monitor, twice to call 'slave 1'
and so on up to 5 presses to call 'slave 4.' This only functions if no call
or communication is in progress. Note: With Tekna Plus monitors (see
the TTekna S Plus manual).
( )
*
This activates auxiliary device 'A1' with the monitor in standby (handset
on or off the hook), call, communication or intercom.
With the monitor in standby and the handset on the hook: This enables
the image from the door panel configured as main to be viewed (if the
bus is busy, the status LED of the monitor will indicate so with a few
quick blinks).
With the monitor in standby and the handset off the hook: It enables
audio and video communication with the door panel to be established
if it has its auto switch-on function activated. This only functions if no
communication is in progress.
In call: A slave monitor enables the image of the door panel to be captured.
With the monitor in standby and the handset on the hook: This makes a
panic call to the guard units configured to receive such calls.
With the monitor in standby and the handset off the hook: It enables a
normal call to the main unit to be made.
During call reception and communication processes, it enables the lock
release to be activated.
( )
*
In advanced programming mode, the default functions of function
buttons
and
OPERATION
-
Call reception: During call reception, the image will appear on the monitor(s)
and the status LED on the master monitor will illuminate (green). If the call is
not answered within 45 seconds, the master monitor's status LED will
illuminate (red), LED
become free.
+ SA
-
To establish communication, lift the handset of the monitor, and the monitor's
status LED (green) and the door panel's LED
Communication with hearing aids
communication with hearing aids equipped with T-mode. Note: Set the
hearing aid switch to the T position, making conversation possible (inductive
loop).
-
The communication will last for one and a half minutes or until the handset is
replaced. After communication, the monitor's status LED will illuminate
(red), the door panel's LED will turn off and the channel will be free.
-
To open the door, press door release button
communication processes: one press will activate the lock release for 3
seconds and LED
can be changed (see the TTekna S Plus manual).
on the door panel will turn off and the channel will
will illuminate.
: The handset of the monitor enables
during the call or
will also illuminate for 3 seconds.
INSTALLATION
2
I
nstallation of the terminal
Avoid dusty or smoky environments or locations near sources of heat.
The monitor can be fixed to an electrical embedding box or directly to
the wall.
Important: For further information, see the TTekna S
Location
Plus manual (code 50122251).
Remember to remove the protective covering from
the front of the monitor once installation is
1.60m
complete.
Surface
4 30
x
WIRING DIAGRAM
D4L-PLUS
Tekna S Plus
M
(1)
JP1
CN4
S
_
V
V
+
A
D
in
out
D1
E
D2
+
D4L-PLUS
Tekna S Plus
M
JP1
CN4
S
_
V
V
+
A
D
in
out
D1
E
D2
+
M =Master.
10
9
1
2
*
Place this power supply as
close as possible to the
first monitor.
FA-Plus/C or FA-Plus
PRI
SEC
~
~
-
-
+ +
CV2
Mains
I
MPORTANT:
For further information about the door panel, sections, distances, wiring diagrams, etc., see the T632 Plus P/T manual.
https://doc.golmar.es/search/manual/ 50122328
3
Embedding box
Screws supplied with
he embedding box.
Tekna S Plus
M
CN4
_
V
V
+
A
D
in
out
(1)
Remove the JP1 jumper
from all of the distributors
except the last.
Tekna S Plus
M
CN4
_
V
V
+
A
D
in
out
Access panel
M
CN3
8
7
6
3
4
5
SW2
SW1
CN1
- +
-
CV1
+
D
A
A
V
V
Mesh
V
V
out
in
in-
in+
out+
out-
DC lock
release