Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2.1
2.2
2.3
E
N
G
L
2.4
I
S
2.5
H
2.6
14

2 - VALVE INSTALLATION

Water Pressure
A minimum of 1,4 bar of water pressure is required for the regeneration valve to operate
effectively. Do not exceed 8,5 bar ; if you face this case, you should install a pressure regulator
upstream the system.
Electrical Connection
An uninterrupted current supply is required. Please make sure that your voltage supply is
compatible with your unit before installation. If the electrical cable is damaged, it must
imperatively be replaced by a qualified personal.
Existing Plumbing
Existing plumbing should be in a good shape and free from limescale. In doubt, it is preferable to
replace it.
The installation of a pre filter is always advised.
By-pass
Always provide a by pass valve for the installation, if the unit is not equipped with one.
Water Temperature
Water temperature is not to exceed 43°C, and the unit cannot be subjected to freezing
conditions. (It could cause irreversible damage to the valve).
Presentation
Brine draw
and slow rinse
Backwash
Service
Service
vessel
indicator
9000 - 9100 - 9500
Fast rinse
Brine
refill

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

91009500

Tabla de contenido