Phase 3: Measuring time:
The pressure is monitored during the 5 minute measuring time. If the pressure drops by > -10
mbar during the measuring time, the leak check is aborted (see error message E1).
Phase 4: Results display:
At the end of the measuring time, the result of the test is shown in the display and you will
hear an acoustic signal. The connected printer automatically prints a test log in duplicate.
The test result (pressure difference in mbar) is the difference between the measured pressure
before and after the measuring time.
Display via Info button
Information about pressure and time is displayed during the automatic leak
check. Press the Info button to select pressure or expired time.
Phase 1:
Pressure build-
up
Pressure in mbar
e.g.
100
Press Info button:
Evaluating the result
An expert evaluates the result of the leak check with consideration of the country-specific
tolerances and on the basis of national laws and regulations.
On the log printout the leak check can be marked as passed with "YES" or "NO".
Log printout
This function is possible only if:
• the printer is connected and switched on
The power LED is green only when the test log is being printed.
• the result of the leak check is shown in the display
Return to stand-by mode:
After a leak check the result or the error number is displayed and an acoustic signal is output
until the test is terminated with the Test button, which returns the system to stand-by mode.
If the leak check was aborted, zero values are printed in the test log.
part no. 27 105 51
Phase 2:
Resting time
Pressure in mbar
e.g.
150
Displays remaining
time
in minutes e.g.
1:55
Press Info button:
Back to pressure
display
Elektronic test device Leak Check LPG PRO
Phase 3:
Measuring time
Pressure in mbar
e.g.
149
Press Info button:
Displays remaining
time
in minutes e.g.
04:5
Press Info button:
Back to pressure
display
Phase 4:
Results display
Pressure difference during the
test in mbar (+ / -) e.g.
-5
Press Info button: Displays
initial pressure at the start of
the measuring time in mbar.
e.g.
149
Press Info button:
back to pressure difference
display
9 / 12