Calibration
Calibration adjustment is permanent and
should only be performed using accurate
calibration weights that match the
requirements for your scale (see the chart on
back). Do not use coins or other household
items to calibrate.
1.
Prepare the required weight for your scale (see
chart on back).
2.
and let the scale adjust to room temperature.
Press ON/OFF to turn the scale on and wait for the
3.
scale to stabilise.
4.
Press and hold the MODE key until the display
shows 'CAL'.
5.
Make sure nothing is on the platform then press
MODE
6.
The display will then
calibration weight.
7.
Place the required
calibration weight on the
centre of the platform.
8.
The display will show
'PASS' then return to
normal weighing mode.
You may now turn the
weighing.