g - For the installation of the air switch, plug
one end of the hose into the pneumatic
button located on the edge of the bathtub,
and the other end into the electric box of
the motor as shown on picture 15.
h - The bathtub must be connected to a circuit
breaker built-in the permanent wiring of
the local it will be installed. This wiring
system must be protected by a DR circuit
breaker of high sensibility (<30mA),
according to the norm NBR 5410.
I - Pieces which contain live parts, except
those pieces provided with extra-low safety
tension not superior to 12V, must be
inaccessible from a person inside the
bathtube.
J – Devices connected to the ground must be
permanentely connected to a fix wiring
system.
6.5

Whirlpool Heater

For the electric installation of the whirlpool
please refer to the manufacturer's manual
16
Line - aspiration
36
Line - jet
Heater
GROUND
The water pump must be grounded
following
the
applicable
connecting a 4 mm² gauge wire to the terminal
located on the motor frame.
CAUTION The incorrect installation of the
:
ground wire or a bad electric circuit network may
cause electric shocks.
15
Hose 1 1/4"
Water pump
Connector