TECHNICAL DATA

Input voltage
Tolerance
Input Frequency
Single Phase Connector Output voltage
Maximum current of single-phase output
Maximum Charge Power
Single Phase connector type
Operating temperature:
Energy meter
Equipment: *Simon guarantees the proper functioning of the Mode 2 charging
solution for supply voltage from normal installation in Single-phase. Any
variation in the standardized conditions may alter the proper operation of the
charging solution.
Case details
Material
Finishing
RAL polyester paint
Degree of protection
Anchor
Weight
Charging pole dimensions:
INSTALLATION
The charging pole will be fixed to the floor so that the lower part of the
connector is located at a height of between 0.9 and 1.2 m above the ground,
according to the United Nations Recommendation for Accessibility for the
Disabled.
For a correct installation, the following steps must be followed:
1. Fix the recharge pole with 4 bolts to the ground ensuring that the height of
the connectors is between 0.9m and 1.2m above ground level.
2. The CGP / CGM power cable entry of the power distributor must be made
through the hole at the bottom of the pole until the connection terminals are
located.
3. Connect the connection terminals (L, N, T) and close the rear access cover.
The recharge pole can be installed in two ways: through bars, in case of
installation without foundation in the base or with anchor bolts, in the case of
installation with foundation in the base.
Option 1
230 Vac
10%
50 Hz
230 Vac
16 A
3.6 kW (max., per outlet)
Schuko CEE 7/4 (230Vac-16A)
-20ºC / 60ºC
B Class UNE EN 50470 1
Aluminium fundition.
Polyesther paint Black and aluminum.
To be agreed.
IP54 / IK10
4 points on the floor
65-70 kg
1550x400x230 mm
Option 2
1: After connecting and installing the recharge pole it is advisable to fill the gap
between the base and floor level with expansive polyurethane foam to protect from
moisture.
The screw and washers to be used in both cases are shown in the following
image:

POWER CONNECTION

1. Open the cover of the back of the charging pole (Rear access cover) with SP-
1/4" safety key. When opening the lid, it is not recommended to remove the
3 position screws located in the bottom and center of the lid, since they are
used as a guide when installing the lid. The locking screws must be removed
in order to open the lid.
2. Pass the power cables of the pole through the base to be able to connect
them:
3. Connect the single-phase power cables to the recharge pole connection
terminal located on the bottom of the pole.
4. Close the rear cover of the urban pole.
5
Connection
strip