ENGLISH
1. DESCRIPTION OF USE
The 1 Outlet M3T2 Charging Wall Box solution (Art.0600561-039) allows the
possibility of managing in the charging box, the electrical vehicles that support
the Recharge Mode 3 (with Type 2 connector according to IEC 62196-2).
The box offers simple to use and intuitive ergonomics that makes it a solution
for any environment: for domestic private use.
The wallbox is designed for being placed either in indoor or in outdoor
environments.
2. SEQUENCE OF OPERATION
1) From the start, the charging box is in a free and operational status (Stand By)
for recharging electric vehicles in Charging Mode 3 (Green LED indicator off).
2) When the user connects the charging cable, the Mennekes Outlet LED
indicator remains fixed to indicate that the electric vehicle is ready to receive
the charge (EV Ready).
If any incident occurs in the vehicle or cable during the charging process, the
Mennekes Outlet LED indicator changes to a fixed red light (Charge Error).
3) Finally, the charging will conclude (End Charge) when the recharge of the
Electrical Vehicle (EV) has concluded from the vehicle, and then the LED
identifier of the Mennekes outlet (EV Ready) shuts off.
3. FEATURES
Number of outlets: 1 cable with M3T2 connector (IEC 62196-2, type 2).
Charging mode: Mode 3 (IEC 62196-2).
Performance: Single-phase and Three-phase (32A)
Electrical Connection System and BUS: Internal with protected terminals for
Power and BUS.
Electrical protection not included (must be included externally in an electrical
cabinet):
- MCB (One per each charging wallbox), overload and short-circuits: The
MCB protection must be curve C with a gauge according to the current
setup of the charge controller up to a maximum of 40A (See section
Electronic charge control settings). The breaking capacity of the MCB
protection device shall be at least 6000A.
- RCD (One per each charging wallbox), direct and indirect contacts: The
RCD must be at least Type A and with a sensitivity of 30mA. The gauge
of this electric protection must be according to the current setup of
the charge controller up to a maximum of 40A (See section Electronic
charge control settings).
- Transient and temporary surge protection: The surge protections
devices must be sized for a maximum voltage between phase and
neutral up to 440V.
Energy Measurement and Monitoring: Local and Remote RS 485 BUS
integrated with Stored Energy Reading (kWh) and the possibility of external
reset of partial measures.
Power regulation: through a potentiometer on the electronic charge controller
that limits the maximum current supplied by the charging point (Between 6 and
32A).
Light indicator: State of the charging process of the type 2 outlet (Green and
Red).
Hose holder accessory included.
Independent power line filter (Not included): see installation section.
Important note: No adapters are supplied with the wallbox and no adapters
shall be used, except those approved by the EV or EVSE manufacturer.
4. CHARGING BOX ELEMENTS
5. TECHNICAL DATA
Input voltage
Tolerance
Input Frequency
Connector Output voltage (Single-phase)
Connector Output voltage (Three-phase)
Maximum current output (Single-phase)
Maximum current output (Three-phase)
Maximum Charge Power
Single and/or three-phase connector type:
Operating temperature:
Equipment: Simon guarantees the proper functioning of the Mode 3 charging
solution for supply voltage from normal installation in Single/three-phase. Any
variation in the standardized conditions may alter the proper operation of the
charging solution.
Case details
Material
Finishing
Degree of protection
Anchor
Weight
Wallbox dimensions:
4
230 Vac / 400 Vac
10%
50/60 Hz
230 Vac
400 Vac
32A
32A
22 kW (max)
IEC 62196-2 type 2
-25º C / 50º C
Rubber case
Polyesther paint Black and aluminum
IP54 / IK10
4 points on the Wall
9 kg
380x260x150 mm