3. INSTALLATION AND PREPARATIONS FOR USE
• For rooms with a volume of between 5 m and 10 m a permanent ventilation of 50 cm free
area will be required unless the room has a door which opens directly the outside air in which
case no permanent ventilation is required.
• For rooms with a volume greater than 10 m - no permanent ventilation is required.
!
Pay attention: Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Technical information for the installer
After removing the packaging material from the appliance and its accessories, ensure that the hob is
not damaged. If you suspect any damage do not use the appliance and contact the store where you
purchased this hob.
The appliance is supplied with an installation kit including adhesive sealing material and fixing
brackets&screws are included with the appliance.
• Cut the aperture dimensions as indicated in Figure - 1. Locate the aperture on the worktop such
that after the hob is installed the following reguirements are ensured;
• 100mm from edge of cooker to combustible materials
• 700mm underside of overhead cupboards, shelving
• 750mm underside of overhead extractor fans.
Min.
25mm
Min.
B
3
3
3
42 mm
Min.
A
Neighbourhood walls
Combustible
Non-combustible
8
2
A[mm]
B[mm]
60
150
40
50
Figure 1