Installation of indoor unit
Step 6: Install drain hose
1. Connect the drain hose to the outlet pipe of indoor unit.
2. Bind the joint with tape.
drain hose
outlet pipe
tape
● Add insulating pipe in the indoor drain hose in order to prevent condensation.
● The plastic expansion particles are not provided.
Step 7: Connect wire of indoor unit
1.Open the panel, remove the screw on the wiring cover and then take down the cover.
panel
2. Make the power connection wire go through the cable-cross hole at the back of indoor
unit and then pull it out from the front side.
3. Remove the wire clip,connect the power connection wire to the wiring terminal according
to the color; tighten the screw and then fix the power connection wirewith wire clip.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
● If the length of power connection wire is insufficient, please contact the supplier for a new
one. Avoid extending the wire by yourself.
● For the air conditioner with plug,the plug should be reachable after finishing installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole partingand the contact parting distance should be more
than 3mm.
drain hose
insulating pipe
screw wiring cover
52
outlet
pipe
N(1)
2
3
yellow-
blue
black
brown
green
Outdoor unit connection