3. OPERATION
The default economy temperature adjustment (when the room is not occupied or there's no detection
on the room) is 16 ºC.
The default anti-frost temperature adjustment (when the occupant is absent from the room for more
than twelve hours) is 7 ºC.
Comfort and economy temperatures can be modified (the anti-frost temperature is fixed):
1. To change the comfort and economy temperatures, the heater must be in MANUAL MODE
(see point 3.3.3).
2. Select the temperature to be changed, comfort, anti-freezing or economy, pressing the
button .
3. Press the
button. The selected temperature will be displayed and it will start to flash.
4. To select the desired temperature please press the
• The comfort temperature range is from 18 to 28 ºC.
• The maximum economy temperature is 18 ºC.
• The economy temperature can NEVER be higher than the comfort
temperature.
• The economy temperature is always 4 ºC less than the assigned comfort
temperature.

3.6 "OPEN WINDOW" FUNCTION

This function is activated when there is a sudden drop of temperature in the room.
When this function is activated (indicator 11, point 3.1), the radiator will switch off, avoiding
unnecessary power consumption.
By closing the window, the radiator will detect a rise in temperature and this function will be
deactivated.
The radiator will switch on again to the mode it was on before the switch-off.
This function is pre-set from the factory. It can be activated or deactivated by the user.
1.
Red light = Comfort
2.
Blue light = Anti-frost
3.
Green light = Economy
or
buttons.
TTi