Helo T2 Instrucciones De Instalación Y Manual De Uso página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
Installation and User's Manual Helo T2
Settings
The control panel has the following sub-menus:
Sauna
¤ Standby. The standby temperature can be set 0–20°C below the target temperature.
The standby temperature can be used also if a sauna user prefers a lower
sauna room temperature; after this user, the temperature can be raised back up
to the target temperature. This property can be applied only through the
calendar function.
General
¤ Set time. The time of day is set by pressing either of the arrow keys until the
correct number appears. Confirming the choice by pressing OK allows the
next number to be chosen.
¤ Set Date. When the correct year is chosen press OK. Now the month can
be set; press OK to confirm. Finally choose the day of the month and press
OK.
¤ Region. Choose the language using this menu. 10 different language
choices can be found in this menu. Press OK after finding the language of
your choice.
You can choose either the Celsius (°C) or Fahrenheit (°F) temperature scale.
Also, you can choose either a 24 hour or a 12 hour clock.
¤ Switch off Time. Set the control panel screen switch off time, time can be set
between 10 sec and 5 min. After making your choice, press OK.
¤ Key Lock. Slow down. Can be set between 10 sec and 5 min after the last
touch of the control panel. Activate by pressing OK.
Unauthorized use of the control panel can be prevented by setting a coded key lock.
The factory code is 0000. The code can be changed by choosing first the current
code and then feeding the new code, each number followed by the OK key.
The coded key lock can be activated from Coded key lock, No or Yes, followed by OK..
¤ Vibration. The purpose of this function is to make using the menus easier: the
vibration emphasizes the settings choices and confirms that an appropriate key has
been pressed. Select Yes or No and confirm with OK..
¤ Further Information. The control panel serial number and the version number of the equipment software are
shown.
Service
¤ Service. You can enter the service menu with the code 124.
¤ Under the Settings menu there are the following submenus.
Bathing time limit. Set the maximum time for the sauna heater on time, monitored
facility 1 min – 18 hours, Timer controlled facility, setting 1 min – 12 hours.
Note! In private use 1 min – 6 hours. After every number selection press OK.
Switch for extending the bathing time. On / Off remote start push button must be
connected. You can set the maximum on time for using the On / Off push button.
External control. Remote start On / Off push button use selection. On /
Off use. Sauna heater use can be controlled with the On / Off push button.
Extend the bathing time. You can extend the time selected with the On / Off push button,
at most up to the maximum time set with the controller.
Please refer to section Switch for extending the bathing time.
Temperature limit. Set the maximum temperature for the sauna, setting 60 – 110 °C.
Overheating limit. Temperature limit setting for the circuit board controlling the sauna
heater.
Setting 50 – 85 °C. Activate / Deactivate. When overheating limit is set on or off.
Corrected temperature. Select No, if you want to see the real time temperature or
select Yes to see the average temperature.
Reset pause timer. The 6 hour pause period can be reset and start a new
12 hour on and 6 hour pause cycle for the sauna heater.
¤ Diagnostics. Relay control. Relay outputs can be controlled separately for troubleshooting
purposes.
PIN code 666.
System status. Shows information on control panel status, room temperature, use time,
software versions.
Heaternet – node list. Shows bus communication information between the control panel and circuit board.
Error log. Shows the last 8 error codes with their date and time. See page 10.
¤ Reset. Resets all settings to default values. Code 421.
For instructions see page 7, Reset.
9
Settings
Sauna
General
Service
OK
General
Set time
Set date
Region
Switch off time
Key lock
Vibration
Further information
OK
Service
Settings
Diagnostics
Restore factory settings
OK
Settings
Bathtime
External Switch Bathtime
Extended Switch Function
Temperature Limit
Overheating Limit
Corrected Temperature
OK