Technical Manual & Parts Lists
AAP26MEG24 Parameter Settings
26M-PAR
Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
111
200-9900 rpm
161
204
270
272
0200-2550
401
436
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off
LED 6: Off
LED 7: Off, Stop at needle down.
LED 8: On, Stop at needle up.
12
VALUE
7
Mode of operation (overedge). MUST SET THIS PARAMETER FIRST!
0
Standard treadle
6800
Maximum speed when "129" is 0, 1, or 2.
0-1
1-CCW
Motor rotation
100
Foot lift modulation
0-5
1
External handwheel sensor configuration.
Drive ratio between motor pulley and handwheel pulley. If handwheel pulley
is smaller than motor pulley, increase this value to slow down sewing head
1000
until measured speed matches speed set with parameter 111. (For
Yamato and Pegasus, setting should be 100; for Rimoldi, setting should
be 124)
0-1
Change from 0 to 1 to save settings
Use code "5913". This disables an input that was causing box to reset
0
itself.
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "3112"
3. Press "E" once and "2.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Go to manual and lower presser foot.
2. Power off-on Efka box holding down the "P" button till "COD" is
displayed.
3. Press ">>" once and enter the number "5913"
4. Press "E" twice and "093" is displayed.
5. Press "+" once, "094" is displayed.
6. Press "P" to exit programming mode with all default values.
7. Reset machine.
Part List Directions
The following pages contain the appropriate
assembly drawings for this unit.
DESCRIPTION