WARNING!
Never use the product for:
- oil mist
- paint mist
- extraction of hot gases (more than 45°C/113°F
continuously)
- explosive environments or explosive substances/
gases
Note: this list is not all-embracing.
Installation
- The installation of this product is exclusively reserved to well
authorised, trained and qualified engineers.
- During installation, always use Personal Protective Equipment
(PPE) to avoid injury. This also applies for persons who enter
the work area during installation.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 meter (local restrictions may apply).
- Never install the product in front of entrances and exits which
must be used for emerency services.
- Mind any gas and water pipes and electric cables.
- Make sure the wall, ceiling or support system are strong
enough to carry the product.
- Ensure the workspace is well illuminated.
- Use common sense. Stay alert and keep your attention to your
work. Do not install the product when you are under the
influence of drugs, alcohol or medicine.
- Make sure that the workshop, in the vicinity of the product,
contains sufficient approved fire extinguishers.
- Air containing particles such as chromium, nickel, beryllium,
cadmium, lead etc., which is a health hazard, should never be
recycled. This air must always be brought outside the working
area.
Use
- Inspect the product and check it for damage. Verify the
functioning of the safety features.
- During use, always use Personal Protective Equipment (PPE)
to avoid injury. This also applies for persons who enter the
work area.
- Check the working environment. Do not allow unauthorised
persons to enter the working environment.
- Protect the product against water and humidity.
- Make sure the room is always sufficiently ventilated; this
applies especially to confined spaces.
Service, maintenance and repairs
- Observe the maintenance intervals given in this manual.
Overdue maintenance can lead to high costs for repair and
revisions and can render the guarantee null and void.
- During service, maintenance and repair jobs, always use
Personal Protective Equipment (PPE) to avoid injury. This also
applies for persons who enter the work area.
- Always use tools, materials, lubricants and service techniques
which have been approved by the manufacturer. Never use
worn tools and do not leave any tools in or on the product.
- Safety features which have been removed for service,
maintenance or repairs, must be put back immediately after
finishing these jobs and it must be checked that they still
function properly.
- Use sufficient climbing gear and safety guards when working
on a higher level than 2 meter (local restrictions may apply).
- Ensure the workspace is well illuminated.
ATTENTION!
Service, maintenance and repairs should only be
performed in accordance with directive TRGS 560 by
authorised, qualified and trained persons (skilled)
using appropriate work practices.
0507291010/260411/A T-Flex/CW
4
INSTALLATION
4.1

Installation height

The recommended installation height of the wall mounting
bracket is 3500 mm (11.5 ft.). However, if the extraction height
is often lower than the standard workbench height (900 mm/3
ft), it is recommended to mount the wall mounting bracket at
3000-3250 mm (9.8-10.6 ft).
Refer to Fig. III on page 39 for detailed measurements
and reach.
A = total height; B = workbench height.
4.2

Tools and requirements

The following tools and requirements are needed to install and
maintain the extraction arm:
- wall mounting material (depending on wall type) +
appropriate installation tools
- wrench 17 (2)
- wrench 13 (2)
- box spanner 13
4.3
Unpacking
Check that the product is complete. The package should
contain:
- extraction arm including wall mounting bracket, tube, hose
500 mm (20 in.), 2 bushes and rope
- rotatable hood RotaHood
- hose 1650 mm (65 in.)
- counterweight + casing
- bush (2)
- mounting material
If parts are missing or damaged, contact your supplier.
4.4
Mounting
The package contains no mounting hardware for the wall
mounting brackets, since the required mounting hardware
depends on the wall type. The wall mounting brackets can be
mounted on e.g.:
- a thin brick or concrete wall (min. thickness 100 mm), using
four threaded rods M10;
- a thick brick or concrete wall, using four cotter bolts
M10x120x60;
- a steel profile (e.g. H-profile), using four threaded rods M10.
For this purpose two square tubes (30x30x3 mm) need to be
mounted to prevent bending.
CAUTION!
Check that the wall composition is strong enough
before mounting the wall brackets.
Before drilling, verify locations of existing gas, water
or electrical conduits.
EN - 10