English – Instructions
WARNING - This device must only be connected to power supplies
compliant with EN60950-1, chapter 2.5 ("limited power source").
EC Declaration of Conformity
Hereby, Vanderbilt International (IRL) Ltd declares that this radio equipment type
is in compliance with the following EU Directives for CE marking:
•
Directive 2014/30/EU (Electromagnetic Compatibility Directive)
•
Directive 2014/35/EU (Low Voltage Directive)
•
Directive 2014/53/EU (Radio Equipment Directive)
•
Directive 2011/65/EU (Restriction of the use of certain hazardous
substances Directive)
The full text of the EU declaration of conformity is available at
http://pcd.vanderbiltindustries.com/doc/SPC
Package contents
•
SPCN320 x1
•
Antenna x 1
•
Mounting pillar x 4
Product overview
The SPCN320 modem provides the SPC controller with a GSM interface. The
modem supports 3G, 2G and GPRS communications, enabling IP communications
to central station software, SPC Connect, and mobile technologies. Analogue
central stations are also supported for SIA, Extended SIA, Contact ID, and Fast
Format.
The modem can be configured to conduct a network survey to choose the highest
signal operator available for the SIM. The "Pay As You Go" (PAYG) credit balance
can also be read by SPC controller when a PAYG SIM is used.
For a description of the GSM features please consult the SPC4xxx/5xxx/6xxx
Installation & Configuration Manual.
Installing the SPCN320
When replacing or installing modules on the SPC system, always ensure
that the mains supply and the battery are disconnected. Ensure that all anti-
static precautions are adhered to when handling connectors, wires,
terminals and PCBs.
Do not reduce the standard-size SIM card to micro- or nano-size.
The SPCN320 must have a standard-size SIM card installed in the unit to operate.
The SIM card must be in the holder before power is applied to the SPC system (see
below for details on installing the SIM card).
See Fig. 1: SPCN320
A Controller PCB (Printed Circuit Board)
B SPCN320 in the primary slot on the controller PCB
C SMA connector for antenna
D Secondary slot
E Tamper link (Terminal T1)
Before installing the GSM module onto the SPC controller, ensure that a functioning
SIM card is installed on the module.
See Fig. 2: Insert SIM Card
A
SIM card holder
B
SIM card
C
Flap on SIM card holder
To insert a SIM card into the GSM module:
1. Place a finger on the SIM card holder (Fig. 2, Item A) and slide the SIM card
holder flap (Fig. 2, item C) to the right
2. Rotate the SIM card holder flap to the 'up' position
3. Slide the SIM card (Fig. 2, Item B) into the SIM card holder flap.
4. Rotate the SIM card holder flap back to its original position.
5. Press and slide the SIM card holder flap to the left to click into place.
Make a note of the unlock code for your SIM card. The code is required
when enabling the SIM card on the SPC system.
To install the SPCN320 (with SIM card):
1. Ensure the AC mains power and battery backup connections are removed.
2. Insert the push-in mounting pillars (included with the module) into the four hole
positions on either the primary slot (left) or secondary slot (right) on the
controller.
3. Align the 16-pin female socket over the 16-pin male connector, ensuring that
the holes on the SPCN320 are aligned with the top of the mounting pillars.
4. Firmly but gently press down to secure the module.
5. Remove the link from the terminal labelled T1 (Fig. 1, item E).
6. Attach the antenna (supplied with the SPCN320) to the SMA connector (Fig. 1,
item C) on the GSM module.
For new system installations, consider removing the knock-out for the
antenna prior to mounting the housing on the wall.
7. Connect the antenna tamper lead to the terminal labelled T1.
8. Mount the antenna on the top of the housing using one of the 12mm knock-out
holes provided. The 12mm knock-out holes align with the primary slot (left) and
secondary slot (right). Ensure that the antenna is unobstructed.
9. Restore the AC mains power and battery backup connections to the controller.
LED Functionality
There are six LEDs on the top of the modem module labelled D1 to D6 (See Fig. 3).
These are used to indicate the status of the modem.
The function of each LED is as follows:
LED
State
Indicates
D1
Flashing
Power
Green
D2
On
Mast
Green
connection
D3
On
Data
Green
Transmission
Configuring the SPCN320
For configuration instructions, please refer to the Configuring Modems sections of
the SPC4xxx/5xxx/6xxx Installation & Configuration Manual.
For 3G performance ensure that the panel firmware is updated with version
3.8 or later.
Technical Data
Network connection
GSM / GPRS (dual band 900/1800 MHz)
Operating current
Max. 130 mA at 12 VDC
Quiescent current
Max. 40 mA at 12 VDC
Operating temperature
-10 to +50 °C
Relative humidity
Max. 90 % (non-condensing)
Mounting
Plug on module to SPC controller
Dimensions (W x H x D)
90mm x 38mm x 25mm (PCB)
Weight
0.130 kg
EN50131-1 approved with control panel
EN 50136-1:2012, EN 50136-2:2013
Standards / approval
VdS Class C
ATS categories
SP1-SP6, DP1
Class 2
Environmental class
Ordering Information
SPCN320.000
GSM Module incl. Antenna
SPCW101.000
External aerial kit
Deutsch – Anweisungen
WARNUNG - Dieses Gerät darf nur an Stromquellen angeschlossen
werden, die der Norm EN60950-1, Kapitel 2.5 („begrenzte Stromquelle")
entsprechen
EG-Konformitätserklärung
Hiermit erklärt Vanderbilt International (IRL) AG, dass dieser Funkgerätetyp den
folgenden EU-Richtlinien für die CE-Kennzeichnung entspricht:
•
Richtlinie 2014/30/EU (Richtlinie über elektromagnetische Verträglichkeit
•
Richtlinie 2014/35/EU (Niederspannungsrichtlinie)
•
Richtlinie 2014/53/EU (Richtlinie über Funkanlagen)
•
Richtlinie 2011/65/EU (Beschränkung der Verwendung bestimmter
gefährlicher Stoffe)
Der vollständige Text der EU-Konformitätserklärung steht unter
http://pcd.vanderbiltindustries.com/doc/SPC
Lieferumfang
•
1 × SPCN320
•
1 × Antenne
•
4 × Montagezapfen
Produktübersicht
Das SPCN320-Modem stellt eine GSM-Schnittstelle für den SPC-Controller zur
Verfügung. Das Modem unterstützt die Kommunikationsstandards 3G, 2G und
GPRS und ermöglicht dadurch eine IP-Verbindungen mit einer
Alarmempfangsoftware, mit SPC Connect sowie mit mobilen Technologien. Des
Weiteren wird die Kommunikation mit analogen Alarmempfangszentralen über die
Protokolle SIA, Extended SIA, Contact ID und Fast Format unterstützt.
Das Modem kann so konfiguriert werden, dass eine Netzwerksuche nach einem
unterstützen Anbieter mit dem stärksten Signal für die SIM-Karte durchgeführt wird.
Bei Verwendung einer Prepaid-SIM-Karte kann das Guthaben über SPC-Controller
ausgelesen werden.
Eine Beschreibung der GSM-Funktionen ist im Installations- und
Konfigurationshandbuch von SPC4xxx/5xxx/6xxx enthalten.
Installieren des SPCN320
Beim Installieren oder Auswechseln von Modulen in die SPC Zentrale,
muss sicher gestellt werden, dass die Anschlüsse von AC-
Hauptstromversorgung und Batterie getrennt sind. Es muss zusätzlich
sicher gestellt werden, dass während der Handhabung von Anschlüssen,
Drähten, Klemmen und Platinen alle erforderlichen Antistatikmaßnahmen
getroffen worden sind.
Die SIM-Karte muss im Standardformat vorliegen und darf nicht auf das
Format einer Micro- oder Nano-SIM zugeschnitten oder gestanzt werden.
Das SPCN320 benötigt für die ordnungsgemäße Funktionsweise eine SIM-Karte im
Standardformat. Die SIM-Karte muss in den dafür vorgesehenen SIM-Kartenhalter
eingelegt sein, bevor das System mit Strom versorgt wird. (Einzelheiten zur
Installation der SIM-Karte siehe unten).
LED
State
Signal Strength
D4
Off
Low 1
Red
Flashing
Low 2 - 3
On
High 4 - 5
D5
Flashing
High 6
Amber
On
High 7
D6
Flashing
High 8
Green
On
High 9
V54550-B102-A200
V54559-B101-A100
zur Verfügung.