Samson S com Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

30
27
24 21
LINK
EXPANDER/GATE
TRIGGER
THRESHOLD
-10
20
T 1
GATE
GATE
50
0
-30
T 2
FAST
OFF +10
-40
dB
dB
SLOW
RELEASE
15 KEY LISTEN SWITCH - When engaged, the signal pres-
ent at the KEY INPUT is sent directly to the channel out-
put.
16 KEY SWITCH- Selects the key input so that an external
signal may trigger the compressor.
17 ATTACK - Adjusts the amount of time the compressor
takes to reach full gain reduction.
18 AUTO - Activates S •com plus' AEG (Auto Envelope
Generator) which dynamically adjusts the attack and
release time based on signal content.
19 RELEASE - Adjusts the length of time the compressor
takes to return the signal to it's original level.
20 INPUT/ OUTPUT METER SELECT SWITCH - Selects
either Input or Output level to be displayed on the
Input/Output Meter.
21 LEVEL - Controls the amount of Output level.
CED
UT
G CHANNEL 2 XLR OUTPUT - XLR Balanced line out-
put.
H CHANNEL 2 1/4" TRS OUTPUT - 1/4" TRS
Balanced line output.
GAIN REDUCTION dB
18 15
12
9
6
4
2
1
-30
-24
COMPRESSOR / LIMITER
RATIO
ATTACK
10
4:1
50
KEY
LISTEN
+10
2
6
15
1
.3
300
+20
dB
mSec
SPECTRA
KEY
CHANNEL 1
-10
BALANCED
INPUT
INPUT
+4
LEVEL
Controls and Functions
7
INPUT / OUTPUT LEVEL dB
-18 -12
-6
-3
0
+3
+6
+9 +12 +18
RELEASE
OUTPUT
0
1
200
.15
3
-10
+10
.05
5
-20
+20
dB
Sec
Sec
AUTO
I/O METER
22 CHANNEL 1 IN/OUT SWITCH- Activates
S•com Channel 1.
23 CHANNEL 2 IN/OUT SWITCH- Activates
S•com Channel 2.
I
KEY
BALANCED
OUTPUT
I
CHANNEL 1 - Same inputs and outputs as
Channel 1.
7
8
9
POWER
POWER
CH 2
CH 2
ENHANCER
5
3
7
OFF
10
OUTPUT