the display manually. The display switches off automatically after 14 days. If you made a mistake or
do not want to switch on the Ionizer, you can simply set the display to '00'. During the first month
of use you must test the pool water every week until you reach the desired balance. After a month
you can reduce the test frequency to once every two weeks. The pH can also be tested with the
test strips. A pH value between 7.0 and 7.6 is the most ideal value for copper ionization. When using
copper ionization it is important that you always use inorganic chlorine. The use of organic chlorine
can cause the copper electrode to become contaminated, preventing it from releasing copper
into the water. The calcium hardness should always be between 5 and 10 °dH. The wrong water
chemistry and/or poor earthing of the pool can result in copper being deposited on parts of the
pool, causing stubborn stains.
Warning! Never add Chlorine, pH regulators or other chemicals through the skimmer or other water
outlets. The temporarily high concentration of chemicals can contaminate the electrode to such an
extent that it can no longer release copper. When adding a flocculant, the Ionizer must be switched
off temporarily.
REPLACEMENT LAMP AND COPPER UNIT
The UV-C lamp has a service life of ±9000 hours and the copper unit ±4000 hours. When the
number '88' is flashing on the display of the Blue Lagoon UV-C Copper Ionizer you must replace the
UV-C lamp and copper unit. You can obtain a replacement set from the dealer where you purchased
the device. Each type of device has its own replacement set with the correct type of UV-C lamp.
Once you have replaced the UV-C lamp and copper unit you can reset the display by holding the '+'
and '-' buttons simultaneously for three seconds.
Replacement set: Copper, Blue Lagoon 40 Watt lamp & test strips, article number: B200012
Replacement set: Copper, Blue Lagoon 75 Watt lamp & test strips, article number: B200013
ADVANTAGES OF UV C TREATMENT
•
Ensures fresh, clean and clear water
•
Disinfects water efficiently and safely
•
UV-C light breaks down organically bound chlorine and prevents chlorine smell and the associated
skin and eye irritation (red eyes)
•
Protects your pool from germs
•
Helps to keep the formation of mould, bacteria and algae under control
•
Can significantly reduce the use of chlorine and other chemicals
•
More environmentally-friendly than traditional methods
CHARACTERISTICS OF BLUE LAGOON UV C COPPER IONIZER:
•
Disinfection through UV-C
•
Disinfection through copper electrolysis
•
316L stainless steel reactor produces up to 35% more UV-C through reflection
•
UV-C lamp service life is ±9000 hours, copper unit ±4000 hours