Easy installation and maintenance
EN
•
2-year warranty against manufacturing defects
INSTALLATION OF THE EARTH DRAWING 1
1. Pull the cable (2) through the strain relief (4) before fitting the synthetic strain relief (4) onto the
earth bolt (1). Position the strain relief (4) at approximately 10 cm from the eye (2) of the earth
cable.
2. Place the eye (2) of the cable onto the earth bolt that is fitted to the housing.
3. Then place a toothed lock washer (3).
4. Fit the strain relief (4), creating a loop of Ø5 cm.
5. Finally place the second toothed lock washer (5) and the lock nut (6) onto the earth bolt.
6. Once the parts have been placed onto the earth bolt in the correct sequence, they can be
tightened with a spanner or a ring spanner number 8.
INSTALLATION OF THE DEVICE DRAWING 2
Never submerge this device in water. The installation must always take place outside of the pool.
Ensure that there is always water flowing through the unit when the lamp is on. The Blue Lagoon
UV-C Copper Ionizer must never be installed behind the PH regulator in your swimming pool
installation. The ideal location is behind the pump and the filter.
1. Determine where the device will be installed.
2. Fit the unit into the circuit using the three-part couplings (I).
3. Fit the supplied pipe clips (O) in fixed positions, press the unit into the pipe clips and tighten the
three-part coupling (I). Ensure that there is sufficient space available (+/- 1 metre) to remove the
lamp (K) / quartz glass (M) for replacement and/or to carry out maintenance.
4. Carefully slide the Blue Lagoon UV-C lamp into the quartz glass (M). Fit the lamp (K) into the
lamp holder (L) and tighten the nut (N) onto the unit by hand.
5. Activate the pump and check the system with regard to flow-through and leakage. Pay
attention to the correct position of the sealing rings (P), both with regard to the connections
and the quartz glass.
6. Place the UV-C device plug into a wall socket that is fitted with a safety ground and a earth
leakage current circuit-breaker (ELCB). Check that the lamp is on by looking through the
transparent sections of the device.
7. The device will be completely switched off if the plug is removed from the socket.
8. Make sure to leave a free area of +/- 1 metre in order to be able to remove the lamp (K) / quartz
glass (M) for the purpose of replacement and/ or maintenance. There must be a minimum space
of 30 cm at the bottom for the replacement of the copper unit (U).
DISASSEMBLY / MAINTENANCE / REPLACEMENT COPPER & LAMP
Always disconnect the mains power during maintenance/disassembly of the device. The device
must be cleaned every three months. When biofilm and/or scale deposits have built up, the quartz