Descargar Imprimir esta página

Malfunctions; Technical Data - diversey TASKI aquamat 10.1 Instrucciones Originales De Uso

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42

Malfunctions

Malfunction
Machine without function
No suction or weak suction
Little or no water

Technical data

Machine
Working width
Spray pump
Rated voltage
Frequency
Rated power, nominal
Dimensions (LxWxH)
Main cord length
Maximum weight of operational machine
Tank capacity +/- 5%
Values according to IEC 60335-2-68
Sound pressure level LpA
Uncertainty KpA
Vibration
Uncertainty K
Splash water guard
Protection class
38
Possible causes
Machine is switched off
No power supply
Main cord defect
Motor does not turn
Main switch is switched off
Motor fault
Dirt in the squeegee
Cover not correctly put on
Seal faulty or not available
Suction hose broken or fitting loose
Recovery tank full/float has triggered
Drainage opening/filter blocked
Pump switched off
Spray nozzles blocked
Spray nozzles removed
Fresh water filter blocked
Troubleshooting
• Switch on the main switch
• Insert the plug into the mains sock-
et
• Replace the main cord
• Contact your service partner
• Switch on the main switch
• Contact your service partner
• Remove the dirt
• Position the cover
• Replace the seal if necessary
• Replace suction hose or tighten fit-
ting
• Turn off the suction motor, empty
and clean tank
• Empty the tank then clean the
drainage opening/filter
• Switch pump on
• Remove and clean spray nozzles
• Attach or replace spray nozzles
• Empty fresh water tank and clean
filter
aquamat 10.1
24
2 x 32
230-240V~
50-60
900
38x38x60
10
12.5
10
70
2.5
<2.5
0.25
IPX4
II
Page
35
35
35
36
cm
W
AC
Hz
W
cm
m
kg
l
dB(A)
dB(A)
m/s2
m/s2

Publicidad

loading