Location and Installation
Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are
thoroughly removed from all surfaces. To prevent injury or damage to the unit, we recommend that the
appliance should be unpacked and set up by two people.
The climatic class can be found on the rating plate. It specifies the ambient temperatures at which the
appliance may be operated. The rating plate can be found inside the appliance.
Climate Class
3
4
5
Maintain a distance of 10 cm between the appliance and walls or other objects for ventilation. Increase
this distance if the obstacle is a heat source.
The appliance should be placed on a solid flat and stable floor to reduce noise and vibration. Level the
appliance by adjusting the feet.
Avoid locating the unit in direct sunlight or near heat sources such as ovens or radiators.
Please make sure the appliance is properly ventilated.
Check that the power supply and voltage used comply with the details on the rating plate. The plug
must be accessible after installation.
Correctly connect and disconnect the plug. When inserting ensure the plug is fully engaged. While
unplugging hold the body of the plug. Never pull the supply cord directly.
If the unit is to be shut down for long period, switch it off and disconnect the plug from socket outlet.
Clean the appliance and leave the door open to prevent odour.
Important! For your personal safety, this appliance must be properly grounded (earthed). This
appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be
inserted into an outlet that is properly grounded and installed. Consult a qualified electrician or service
centre if you do not completely understand the grounding instructions. If doubt exits whether the
appliance is properly grounded, have a qualified electrician check the circuit to make sure the outlet is
properly grounded.
If the cable does not reach the nearest socket, either rearrange your store layout or ask a qualified
electrician to fix a new socket.
If power is cut off, wait for at least 3 minutes before restarting the appliance to avoid damaging the
compressor.
Slide the shelf/drawer into place.
Note: If the unit has not been stored or moved in an upright position, let it stand upright for
approximately 24 hours before operation.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water.
P2M053STD-Ver1.1
Max. Ambient Temperature
25
30
40
6
Relative Humidity
60%
55%
40%
GB